TI032-3W 400-032-001-B 30/11/06 1/2
TI032-3W

Installation and User Guide

Programmable Wall Switch

The TI032-3W switch can be used in a single-pole or 3-way installation
with the following types of lighting:
• Incandescent
• Halogen
• Low-voltage halogen with transformer
• Fluorescent
The
TI032-3W
switch cannot be used with a load below 40 W or above
500 W.
nCut power at the circuit breaker to avoid electric shock.
oRemove the existing switch. (For a 3-way installation, identify and
label the wire that is connected to the “common” screw.)
pInstall the new switch (refer to the appropriate section below).
qApply power at the circuit breaker.
SINGLE-POLE INSTALLATION
Connect wires "2" and "C" of the TI032-3W to the line (120 V) wire.
EXISTING 3-WAY INSTALLATION
Connect wire "C" of the TI032-3W to the "common" wire, identified when
removing the old switch. Connect the other two TI032-3W wires to the
two remaining wires.
At the other 3-way switch, connect the jumper wire between the "com-
mon" screw and the screw where wire "1" of the TI032-3W is connected.
NEW 3-WAY INSTALLATION
The jumper wire is not required in this installation. A single-pole
switch can be used as the other switch in a 3-way installation.
nPry the switch door open from the
bottom using a small screwdriver.
oEnsure the ON/OFF selector is set
to ON.
pReset the switch using a paper clip.
0:00 and MO will flash.
If the display is blank:
Ensure the ON/OFF selector is properly engaged in the ON posi-
tion. Push it to the right using a small screwdriver.
If the programmable switch controls a lamp equipped with a
built-in On/Off switch, ensure the lamp switch is set to On.
Ensure the light bulb is not burned out and is tightly screwed in its
socket.
EXISTING 3-WAY INSTALLATION
If either switch does not work properly, rewire the jumper between the
"common" screw and the other screw.
WARNING : Before replacing the light bulb, place the ON/OFF
selector in the OFF position. Failure to do so might damage the
switch.
NOTE: The switch displays the time in 24-hour format by default or
following a reset.
nTo change to 12-hour format (or vice versa), proceed as follows:
a) Press one of the control buttons to ensure the MAN or
AUTO indicator is displayed.
b) Press the MIN and HOUR buttons simultaneously and brief-
tly (0:00 display = 24-hour, 12:00 display = 12-hour ).
oSet the time using the HOUR and MIN buttons. If you have
selected the 12-hour format, ensure that PM appears on the
screen when an afternoon time is displayed.
pSet the day by using the DAY button.
qPress one of the control buttons or close the switch door to
return to normal operation.
nApplications 1.
oInstallation 2.
NOTE A:
The white wire is not the neutral wire but the wire going to the
load.
Line
Neutral See NOTE A
120 VAC
Line
Neutral
120 VAC
Red
120 VAC
Jumper Red 3-wire cable
See NOTE A
pPower-On 3.
qSetting the Clock 4.
120 VAC See NOTE A
Control (4)
Reset
On/Off
selector
400-032-001-B ENG (print at 90%).fm Page 1 Thursday, November 30, 2006 8:52 AM