INSTALLATION GUIDE FOR:

Battery Back-Up

Printed in U. S. A.

Form No. 128-4503

SIREN MOUNTING:

1.Find a suitable spot to mount the siren in the engine compartment (firewall, sidewall, etc.).

2.Using siren bracket as a template, drill (2) 1/8" diameter holes in mounting surface.

Note: If mounting on the firewall, make certain there is no interference on the other side of the firewall.

3.Secure bracket using screws provided with kit.

4.Secure siren to the bracket using bolts and lock washers provided.

WARNING - Open end of siren must point downward to prevent water collection in horn end of siren.

WIRING:

RED WIRE - Splice to +12 VDC battery source lead of existing alarm.

BLACK WIRE - Splice to chassis ground lead of existing alarm.

WHITE w/ BLACK STRIPE WIRE - Connect to the positive siren output from the alarm module.

BLACKWIRE-SPLICEINTOCHAS- SIS GROUND LEAD OF EXISTING ALARM.

l

BACK-UP SIREN

OFF

ON

 

NOTE: BEFORE MAKING

 

CONNECTION, MAKE

 

SURE KEY IS IN THE "OFF"

 

POSITION AS SHOWN.

 

WHITE w/BLACK STRIPE - CONNECT TO

THE POSITIVE SIREN OUTPUT FROM THE

ALARM MODULE.

RED WIRE - SPLICE TO +12VDC BATTERY

SOURCE LEAD TO EXISTING ALARM.

l

NOTE : MAKE SPLICE CONNECTIONS AS CLOSE TO EXISTING ALARM AS POSSIBLE.