Avaya SG203/SG208 Security Gateway Hardware Installation Guide

Required tools

The security gateway chassis can be mounted in a standard 19-inch equipment rack. Rack mounting requires a Phillips-head screwdriver, the device rack mount bracket kit, and four screws to match the rack. (Screws for attaching the mounting brackets to the chassis are not provided.) Instructions for rack mounting are provided in the section “Rackmount” on page 18.

Safety recommendations

When using the SG203/SG208 security gateway devices, follow these safety guidelines:

Keep the chassis area clear and dust-free during and after installation

Keep the ventilation gratings clear of any blockages

Do not rest equipment in excess of 10 pounds on top of the chassis

Disconnect all power before mounting or unmounting a unit from an equipment rack

Never assume power is disconnected from a circuit, always check

Circuit Breaker (15A) Warning

WARNING: This product relies on the building’s installation for short- circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductor (all current-carrying conductors).

SELV Circuit Warning

WARNING: The Ethernet 10/100/1000BASE-T ports contain safety extra- low voltage (SELV) circuits. Do not connect to a telephone line.

Desktop

To install on a desktop, allow sufficient depth in the rear for cabling and on the sides for ventilation flow.

March 2004

Installing SG203 and SG208 Security Gateway 17

Page 17
Image 17