“HOME” to camera four on an alarm. Homing to camera four will occur on an alarm regardless of the switch positions of the other cameras. If camera four is in the bypass mode, it will still home upon an alarm and return to the sequence or other selected modes upon the completion of the alarm. If cameras 1, 2, and 3 are sequencing, and camera 4 is in the bypass mode, upon an alarm the switcher will home to camera 4 for the alarm duration; then, when the alarm stops, it will continue the sequence from where it was when the alarm was triggered.

NOTE: Upon powering up the 4PSWT, the switcher waits one dwell

time to initialize. This may take from 1 second to 1 minute depending on the present dwell time setting.

POWER

The switcher is powered by the included wall transformer. The unit can be powered from 9 to 12VDC. The center post of the DC Coax is POSITIVE.

CONNECTIONS

The VIDEO inputs are BNC type connectors. The inputs are 75 ohm terminated and require 1V P-P. The output is 1V P-P and will drive a 75 ohm load. Connect the video cameras to the switcher in the desired order. Connect Video out to your VCR or Monitor. Plug in the DC Coax connector. The switcher is now operational. Select the desired front panel controls and adjust the dwell.

_____________________________________________

Internal Jumper Settings:

JP2=open JP3=shorted

4

Page 4
Image 4
AVE 4PSWT operation manual Power, Connections