Appendices 55
• History Key Sequence - This option allows you to defi ne the key combina-
tion that enables History mode. The default key sequence is Ctrl-F9.
• Clear History Key Sequence - This option allows you to defi ne the key
combination that clears the history buffer while in History mode. The
default key sequence is Ctrl-F11.
• Break Key Sequence - This option allows you to confi gure the key combi-
nation that generates a break condition. The default key sequence is Alt-B.
To confi gure an AVRIQ-SRL module:
1. Press Ctrl-F8. The Confi guration Screen will appear.
2. Select a parameter to change. You can navigate the Confi guration Screen
using the Up Arrow and Down Arrow keys.
3. Modify the selected value using the Left Arrow and Right Arrow keys.
4. Repeat steps 2 and 3 to modify additional values.
5. Press Enter to save your changes and exit the Confi guration Screen.
- or -
Press Esc to exit the Confi guration Screen without saving the changes.
Creating an AVRIQ-SRL macroPressing the Page Down key when the Configuration Screen is displayed will
provide access to the Macro Configuration screen. The AVRIQ-SRL can be
configured with up to 10 macros. Each macro can be up to 128 characters
in length.
To create a macro:
1. Select the AVRIQ-SRL you wish to confi gure and press Ctrl-F8 to activate the
Confi guration menu.
2. When the Confi guration menu appears, press Page Down to view the Macro
Confi guration screen. The Macro Configuration screen shows the 10
available macros and the associated key sequences, if any, for each.
3. Using the Up Arrow and Down Arrow keys, scroll to an available macro
number and highlight the listed keystroke sequence. Type the new macro
keystroke sequence over the default. Any combination of Ctrl or Alt and a
single key may be used. When you have fi nished entering the keystroke
sequence that will activate the new macro, press the Down Arrow key.
4. On the line below the macro keystroke sequence you just entered, type the
keystroke sequence that you wish the macro to perform.