AXIS M3014 Network Camera

Hardware overview

Connectors

Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet (PoE).

Caution

Due to local regulations or the environmental and electrical conditions in which the product is to be used, a shielded network cable (STP) may be appropriate or required. Any network cables that are routed in outdoor environments or similar shall be shielded (STP) and intended for their specific use. Make sure that the network switch is properly grounded. See Electromagnetic Compatibility (EMC) for regulatory requirements.

Control button - The control button is used for:

Connecting to an AXIS Video Hosting System service. See page 34. To connect, press and hold the button for about 1 second until the Status LED flashes green.

Connecting to AXIS Internet Dynamic DNS Service. See page 35. To connect, press and hold the button for about 3 seconds.

Resetting the product to factory default settings. See page 40.

LED indicators

LED

Color

Indication

 

 

 

Network

Green

Steady for connection to a 100 MBit/s network. Flashes for network activity.

 

Amber

Steady for connection to a 10 MBit/s network. Flashes for network activity.

 

Unlit

No network connection.

 

 

 

Status

Green

Steady green for normal operation.

 

Amber

Steady during startup and when restoring settings.

 

Red

Slow flash for failed upgrade.

 

 

 

Power

Green

Normal operation.

 

Amber

Flashes green/amber during firmware upgrade.

 

 

 

Note

The Status LED can be configured to be unlit during normal operation. To configure, go to Setup > System Options >LED. See the online help for more information.

The Status LED can be configured to flash while an event is active.

The Status LED can be configured to flash for identifying the unit. This can be done under Setup > System Options >