B&B ELECTRONICS PRODUCT INFORMATION
Integrate – Expand – Simplify
© 2002 by B&B Electronics. All rights reserved.
Model: 232HSP
RS-232 High Energy
Surge Protector CE
Overview
The Model 232HSP is designed to help protect against lightning strikes, power surges, and other types of voltage disturbances. Pins 2 through 8 and 20 are protected on a
Connections
1.The 232HSP should be located as close as possible to the equipment being protected.
2.A good ground connection must be made between the 232HSP and earth ground. This can be done with the two terminal posts on the top of the unit or the two mounting brackets.
3.The earth ground connection should be kept as short as possible for best performance. As a recommendation a minimum of 10 gauge copper wire at no more than 3 feet should be used. If it is not possible to achieve the short distance a braided cable made specifically for grounding purposes should be used.
4.The chassis ground of the equipment should be connected to the buildings 3 prong plug ground.
Specifications
Clamping Voltage, stage one: | Min. 72 VDC, Max.108 VDC | |||||||||||||||
Series Resistance, stage two: | 2.7 Ohms |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Clamping Voltage, stage three: | Min. 14.3V, Max 15.8 V | |||||||||||||||
Clamping Time: | Less than 5 | |||||||||||||||
Connectors: | Line side: | |||||||||||||||
|
| Equipment side: | ||||||||||||||
Dimensions: | Approximately 5.3L X 4.4W X 1.9H in (13.5 x 11.2 x 4.8 cm) | |||||||||||||||
Weight: | Approximately 11.8 Ounces (.3 kg) | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DECLARATION OF CONFORMITY |
| |||||||||||||
| Manufacturer’s Name: | B&B Electronics Manufacturing Company |
| |||||||||||||
| Manufacturer’s Address: | P.O. Box 1040 |
| |||||||||||||
|
|
| 707 Dayton Road |
| ||||||||||||
|
|
| Ottawa, IL 61350 USA |
| ||||||||||||
| Model Number: | 232HSP |
| |||||||||||||
| Description: |
|
| |||||||||||||
| Type: |
| Light industrial ITE equipment |
| ||||||||||||
| Application of Council Directive: | 89/336/EEC |
| |||||||||||||
| Standards: |
| EN |
| ||||||||||||
|
|
| EN 61000 |
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |||||||
| William H. Franklin III, Director of Engineering |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
International Headquarters:
707 Dayton Road P.O. Box 1040 Ottawa, IL 61350 USA
Westlink Commercial Park Oranmore Co. Galway Ireland