![](/images/new-backgrounds/1189284/18928439x1.webp)
Basic Configuration | Port Addresses |
|
|
0000* | 3F8, 3E8 |
|
|
0001 | 2F8, 2E8 |
|
|
0002 | 390, 398 |
|
|
0003 | 100, 108 |
|
|
0004 | 110, 118 |
|
|
0005 | 120, 128 |
|
|
0006 | 130, 138 |
|
|
0007 | 140, 148 |
|
|
0008 | 1E0, 1E8 |
|
|
0009 | 220, 228 |
|
|
000A | 260, 268 |
|
|
000B | 280, 288 |
|
|
000C | 290, 298 |
|
|
000D | 330, 338 |
|
|
000E | 340, 348 |
|
|
000F | 350, 358 |
|
|
0010 | 300, 308 |
|
|
0011 | 310,318 |
|
|
Table 1: 232PCC2 Basic Configuration Table
*Indicates COM mode addressing. Addresses 3F8/3E8 are the standard addresses for COM1/COM3. Addresses 2F8/2E8 are the standard addresses for COM2/COM4. All other basic configurations use block mode addressing at non- standard base addresses. Windows 95 enumerates any COM port at a non- standard address starting with COM5.