Chapter 4: Specifications

Serial Ports

 

Modem Port:

RS-232, DTE, DB9 male connector

Data Rates:

600 – 115,200 baud, N-8-1 only

ISP:

User configurable for primary and

 

secondary (fallback) ISP accounts

 

Supports standard (AT command set)

 

modems

Local Port:

RS-232, DTE, DB9 male connector

Data Rates:

300 – 115.2 kbps

Data Bits:

5, 6, 7, or 8

Stop Bit:

1, 1.5, or 2

Parity:

None, even, or odd

Serial Data Buffer Size:

60 Kbytes

Triggers for Data Delivery

 

Time Based Trigger:

Configurable from once per minute to

 

once per month

Buffer Trigger:

Configurable 10 – 80% of buffer capacity

Digital Input:

Active high or low, 0 – 5V input,

 

5 ms min. pulse width

 

Removable terminal block connection

Data/Fault Notification:

E-mail or pager

Data Delivery:

FTP or e-mail attachment (MIME)

Timestamp:

User enabled, new data time-stamped

 

after 1 minute of idle

Number of Polling Strings:

10 user definable, each with

 

independent transmit schedule

Max. Polling Strings Length:

35 bytes per string

Email Addresses Supported: 10

Pager Supported:

1

FTP Addresses Supported:

2

Mounting:

Desktop or panel mount using provided

 

holes in case flange

Power Requirements:

10–30 VDC, 650 mW maximum

 

Removable terminal block connection

Indicators:

3 LED’s for power/status, modem, and

 

local serial port activity

Size:

6.5 x 4.9 x 1.5 in (16.5 x 11.2 x 3.5 cm)

Shipping Weight:

0.9 lb (0.4 kg)

Software (included):

CD for Windows 95/98/ME/2000/XP/NT 4.0

Documentation Number DCDSS11702 Manual

Appendix A

9

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics Ltd – Westlink Comm. Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

Page 12
Image 12
B&B Electronics DCDSS1 manual Specifications, Serial Ports, Triggers for Data Delivery