Serial Data Configuration
In order for the host device that is connected to the master port to select any of the five ports, the Smart Switch must be set to match the host's communication format. Dipswitch “SW1” is used to select the communication format of the Smart Switch. Switch positions 1 through 3 select the baud rate. Switch position 4 selects 7 or 8 data bits. Switch position 5 determines if parity is enabled or disabled.
NOTE: A data format of 7 data bits, no parity and one stop is not allowed.
Switch position 8 selects the port configuration, see section titled "Port Configuration". Refer to Table 1. Always power down the
smart switch when changing switch settings.
RS-485 Support
Port power of about 30 mA may be applied through the DTR line (Pin 4) of the slave ports with jumper
Table 5. Port Power Jumpers
Jumper
“OFF” | DTR passed * |
“ON” | Port Power |
* = FACTORY DEFAULT
6 | 232XS53800 Manual |
B&B Electronics | PO Box 1040 |
PH (815)