Server Properties Configuration

Port Status

This field indicates whether a serial port is connected via the Serial Server to a virtual COM port of a device on the network.

TCP/UDP Port

This sets the port number for connection. The default port number for the ESP901 is 4000. The default port numbers for the ESP902 are 4000 and 4001 for serial ports 1 and 2 respectively.

In all modes of operation, Direct IP or Virtual COM, the port number set in the Server Properties menu must match the Virtual COM or socket software port settings.

Note:

Example: The Virtual COM default setting is TCP/UDP Port 4000. If the port # property is changed to 4001, the virtual COM port will have to be changed to 4001. The hardware settings can be changed from the ESP Manager or Console Configuration Menu. The Virtual COM port setting also can be changed within the Device Manager of the computer on which it is installed.

Serial Port Mode

Serial Port Mode allows configuration of the serial server for the following modes of operation:

Console – When this mode is selected and the server is updated, a PC running a communications program such as HyperTerminal can communicate with the Serial Server via the Console Mode serial port (the serial Port on ESP901 or Port 1 on ESP902), displaying the Server Properties screen and allowing configuration of the server and its ports.

Upgrade – When this mode is selected and the server is updated, firmware can be uploaded into the Serial Server via the Console Mode serial port or a virtual COM port mapped to the number of the Console Mode serial port.

Default – When this mode is selected and the server is updated, it will revert the server to its default configuration.

RS-232– When this mode is selected and the server updated, the selected serial port will become an RS-232 serial port on the server.

RS-422– When this mode is selected and the server updated, the selected serial port will become an RS-422 serial port on the server.

Manual Documentation Number: ESP901-902_4105m

Chapter 5

37

Server Properties Configuration

RS-485– When this mode is selected and the server updated, the selected serial port will become an RS-485 serial port on the server.

Connection At

When the Connection Mode field is set to Client or Client (no heartbeat), this field becomes active, allowing the ESP901/902 (acting as a client) to connect to the server either on Power up or on Data Arrival (first character arriving).

Max Connection

This field allows the user to configure the Serial Server to have up to eight TCP connections.

Remote IP Address

This is a security feature activated by entering the IP address of the desired client. The Serial Server will only communicate with the listed IP address and all other requests for connection will be filtered out. The Serial Server must be set up as a TCP or UDP Server to use this feature. The default setting is 255.255.255.255.

If Paired Mode is not being used, do not change this setting until the application has been tested and is communicating properly. Then activate the address filtering feature.

Note:

Refer to Chapter 1 Paired Mode

Update/Save

Server properties must be updated separately for each serial port. Updating varies slightly depending on which of the four configuration user interfaces are used.

Updating the Server Properties in ESP Manager

From the Server Properties screen, click the Update button to store the configuration settings for the currently selected port. The vcomui dialogue box will appear indicating you must restart the device before the new settings will take effect. Click Yes.

38

Chapter 5

Manual Documentation Number: ESP901-902_4105m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

www.bb-elec.com

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

www.bb-europe.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

www.bb-europe.com

Page 23
Image 23
B&B Electronics Multi-Interface Ethernet Serial Servers, RS-485 Port Status, TCP/UDP Port, Serial Port Mode, Connection At

RS-422, RS-232, RS-485, Multi-Interface Ethernet Serial Servers specifications

B&B Electronics is renowned for its reliable and efficient solutions for industrial communication, and their Multi-Interface Ethernet Serial Servers stand out as versatile tools for connecting legacy serial devices to modern Ethernet networks. The compatibility with various serial communication protocols, including RS-485, RS-232, and RS-422, makes these servers indispensable in numerous applications that require reliable data transfer.

One of the main features of B&B Electronics Multi-Interface Serial Servers is their ability to support multiple serial communication standards. This flexibility allows businesses to integrate older equipment with newer technologies seamlessly. The servers can act as a bridge, ensuring that data from RS-232 devices can be transmitted over Ethernet networks without modification.

These servers also boast a robust design that is built for industrial environments. With an operating temperature range suitable for harsh conditions, they ensure uninterrupted service in settings such as factories or outdoor installations. The metal housing of the devices provides durability and protection from physical damage, ensuring long-lasting performance.

In terms of connectivity, B&B Electronics Multi-Interface Serial Servers come with numerous options to accommodate different network configurations. They support various IP addressing schemes, allowing for easy integration into existing network infrastructures. Their Ethernet compatibility means they can handle high-volume data traffic, making them ideal for applications that demand high-speed communication.

Another significant feature is their user-friendly configuration options. The servers can be configured via a web interface, providing an intuitive and straightforward approach for users to set up and manage their devices remotely. This feature is especially beneficial for businesses with distributed operations, as it allows for easy monitoring and management from a central location.

The serial servers also incorporate advanced technologies such as TCP/IP and UDP protocols, enhancing data transmission reliability. This ensures that even in instances of network interruptions, data is not lost, thus maintaining the integrity of information being communicated between devices.

In summary, B&B Electronics Multi-Interface Ethernet Serial Servers serve as a crucial link between legacy serial devices and modern Ethernet networks. Their flexibility, robust design, and user-friendly features make them a preferred solution for industries looking to improve their communications infrastructure and streamline their operations. With the integration of cutting-edge technologies, these servers not only meet the current demands but also adapt to future advancements in network communications.