Page 5
1. AC fuse holder - Holds the AC Line fuse. This fuse is an 8 Amp / 250 Volt
Slow Blow fuse. Replace with same type and value f use
only.
2. AC Input receptacle - For attaching the supplied AC power cord to the
amplifier.
3. Speaker outputs - For connecting the speakers to the amplifier. Explained
further on page 8.
4. Amplifier control muting input/output -
To provide remote switching of mute on/off of the amplifier.
Explained further on page 5.
5. Line level outputs - For connecting signal to another amplif ier (daisy chaining).
6. RCA inputs - For connecting signal patch cables (interconnects) from the
preamplifier to the amplifier to pass signal.
7.Level controls - For adjusting the input level to the amplifier. Explained
further on page 6.
A control is provided on each AV2500 series II amplifie r to allow remo te switching of
mute on/off. The preamplifier’s control output, such as is provided with B&K series
preamplifiers, can be utilized to provide a control signal to the AV2500 series II. If more
than one amplifier is being controlled, the control signal can be extended to include
each successive unit by simply running an RCA type audio cable from the CTRL OUT
connector of the first amplifier to the CTRL IN connector of the next unit (commonly
referred to as ‘daisy chaining’). An example of how to connect two amplifiers is
illustrated in figu re B.
If a source other than a B&K series preamplifier is used to control multiple amplifiers,
only the control output voltage f rom the source is critical. It must be within the range, as
indicated on the rear panel, 5-24 volts DC is required. The amplifier will provide each
successive amplifier with a control voltage of 12 volts DC for reliable operation. The
amplifiers control output may be used as a source of 12 VDC @ 125 mA for other user
applications as well.