12Inch Flexible Probe

Combustibles Sensor & Sensor CoverInstruction 19-9336Audible AlarmVisual Alarm LED Combustible Gas Leak Detector

12Inch Flexible Probe

Battery Door

Combustibles Sensor & Sensor Cover

Instruction 19-9336

Rev. 0 – October 2005

Audible Alarm

Instrument Ready - Slow beep. The beep rate is about once per second with no gas detected.

Combustible Gas Indication - Beeps at a rate that increases along with the gas concentration.

Sensitivity - Produces an increasing frequency tone when sensitivity changes from low to high, and produces a decreasing frequency tone when sensitivity changes from high to low.

Dead Batteries - High frequency tone, fol- lowed by the instrument turning itself OFF.

Sensor Error - Rapidly changing high and low frequency tones.

Visual Alarm LED

Power ON - Rapidly flashes green during warm- up (approximately 60 seconds).

Power OFF - Glows red just before power OFF.

Instrument Ready - Slowly flashes green. The flash rate is about once per second with no gas detected.

Combustible Gas Indication - Flashes green at a rate that increases with the gas concentration.

Sensitivity Change - Color changes from red to green.

Low Battery - Flashes orange instead of green when checking for gas leaks. Typically 1 hour of operation left after LED changes to orange. Change batteries as soon as convenient.

Dead Batteries - Glows red, followed by the instrument turning itself OFF.

Sensor Error - Flashes alternating green and red.

One Button Control

Press once for half second to turn instrument ON.

Press and hold for 2 seconds to turn instrument OFF.

Double press to toggle sensitivity between high and low.