B-1
B 7 1 C P
Brake
Voltage
7 - 208/230/460 VAC
AMP Size
0 - 8 AMPS
1 - 16 AMPS
2 - 30 AMPS
3 - 55 AMPS
4 - 135 AMPS
C - Control only
Enclosure Type
A - Open
B - NEMA 1
C - NEMA 12
D - NEMA 4
P - PANEL

Dynamic Brakes

There are 2 styles of brakes built by Baldor. Verify the type of brake first.
Old Style
The “old style” brake has most parts still available. The major exception is the braking module ( A ) which is
no longer available.
B Q 7 1 6
Brake
UL Style
Voltage
AMP Rating
Control Only
Enclosure
New Style
The New style brake parts list is covered in the brake manual. Please see the manual for detail parts
information.
0C P
Custom Product
Manual: see PR802 Binder.
Manual: MN802.
— —