Modulated remote sensors require specially
designed cable for efcient sensor performance.
Extension cable is available in 100 foot (30m)
lengths.

Extension Cable

used with the compression ttings, at
right, to achieve maximum protection
to sensor cables.
I.D. = 5/16"; O.D. = 7/16".

Accessories for High Performance Modulated Remote Sensors

PVC-6 6 feet (1,8m)
PVC-30 30 feet (9m)

Hookup of LR300 and PT300 Hookup of SP300D, SP300L, LP400WB, SP1000V

Hookup of SP320D

Sensor Hookup Diagrams for MA3-4 MICRO-AMP Modules (continued)
Remote sensor cables may be run up to 30 feet (9m) away from the MA3-4
amplier. All sensor models are available from the factory with 30 feet of
cable, installed as an option.
When splicing additional cable to the standard 6-1/2 foot length, it is
important to use a separate shielded cable for emitter and receiver wires.
Combining emitter and receiver wires together in the same cable (even if
the cable is shielded) will result in direct coupling of the emitter signal to
the receiver leads.
This is called "cable crosstalk" and will not allow full amplier sensitivity
setting without an amplier "lock on" situation, which appears as a con-
tinuous LIGHT condition. Banner offers 100 foot (30m) lengths of sensor
extension cable (see below) which, if used for cable splicing, will minimize
the chances for cable crosstalk.
IMPORTANT : Cable Splicing Information
WARNING MICRO-AMP®
Systems do NOT
include the self-checking redundant circuitry neces-
sary to allow their use in personnel safety applica-
tions. A sensor or amplier failure or malfunction
can result in either an energized or a de-energized
output condition.
Never use this product as a sensing device for personnel protection. Its
use as a safety device may create an unsafe condition which could lead
to serious injury or death.
Only MACHINE-GUARD and PERIMETER-GUARD Systems, and
other systems so designated, are designed to meet OSHA and ANSI
machine safety standards for point-of-operation guarding devices. No
other Banner sensors or controls are designed to meet these standards, and
they must NOT be used as sensing devices for personnel protection.
Heavy duty PVC tubing used to
protect sensor cable in applications
involving moisture and/or corrosive
materials. I.D. = 1/4"; O.D. = 3/8".
Extension Cable
Model
ESC-100
RSC-100
SSC-100
EC300E-100
EC300R-100
EC320-100
Used on Sensor Models # of
Wires Wire Colors
White, Green, Shield
Red, Black, Shield
White, Green, Red, Black,
Shield
White, Shield
Red, Shield
White, Shield, Red, Shield
PT200, PT250, PT400,
SP300RL
LR200, LR250, LR400,
SP300EL
SP300D, SP300L, LP400WB,
SP1000V
LR300
PT300
SP320D
3
3
5
2
2
4
Banner Engineering Corp. 9714 10th Avenue No., Minneapolis, MN 55441 Telephone: (763) 544-3164 FAX (applications): (763) 544-3573

Cable Protection

AC-6 6 feet (1,8m)
AC-30 30 feet (9m)
This is mild-steel exible tubing