3. Installation Guide lines
Suggestion
Lamp runtime is
105 hours
It is advisable to
adjust the Z-axis
of the lamp to
obtain maximum
light output
(see owners manual)
<ENTER> to confirm
Menu3-1
The user can now adjust the Z-axis byfo llowingthe next procedure.
How to readjust.
1. On the side of the inputs, turn the retaining bolt a quarter counter clockwise.
2. Flip the cover to the left side and take off. (image 3-16)
3. Start up the adjustment mode and select Service. (menu3-2)
4. Select Lamp. TheZ-axis indication (lamp menu in service mode) will be helpful while turning screw B . (menu 3-3)
5. Loosen the nut A (image 3-17)on the back of the lamp casing (nutdriver 10).
6. Adjust the screw B (image 3-17)with an Allen key by turning a little clockwise until the maximum light output is reached (the
maximum value of the Z-AXIS indication on the lamp menu).
7. Fasten the n uton th e back of the lamp casing to secure this position (nutdriver 10).
ADJUSTMENT MODE
Select a path from below :
RANDOM ACCESS
INSTALLATION
SERVICE
Select with or
then <ENTER>
<EXIT> to return
Menu3-2
SERVICE
IDENTIFICATION
CHANGE PASSWORD
CHANGE LANGUAGE
CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION
NETWORK
LAMP
DIMMING
MORE...
Select with or
then <ENTER>
<EXIT> to return
Menu3-3
LAMP
Constant Light output [OFF]
Using [RS port]
Mode [NORMAL]
Serial number : R101111
Article number : R9840xxx
Run time : 10 hours
Remaining run time : 490
hours
Number of strikes : 10
Z_AXIS : 100
Select with or
then <ENTER>
<EXIT> to return.
Menu3-4
Image3-16
Lampadjustment access
22 R5976801 SLMR9+ 20/10/2004