C. Troubleshooting
C. TROUBLESHOOTING
C.1 Error codes
Overview
Thefollowing table gives an overview of some important error codes displayed on the LED display of the projector.
Errorcode Description Caused by Action
2002 lampstart failed
• hotrestrike
• lampwithman ystrikes
• maximumruntime exceeded
• Letcooldown the lamp for at
least3 minutes.
• Replacethelamp with a ne w
one
6000 tiltswitch tiltangle is out of specifications
• Correctprojectioninstallation.
• Changethe tilting so thatthe
tiltangle becomes within the
specifications..
5002 ambientovertemperature ambient temperature sensed by
theprojector is above 45°C
Cool down the installation
environment.
1100 Lampovertemperature lamp to hot Let cool down the lamp
3004 Topfan error fanis not turning
failure
Calla qualified service engineer
3005 Anode fan error fanis not turning
failure
Calla qualified service engineer
3006 Cathode fan error fanis not turning
failure
Calla qualified service engineer
2000 NoL PS detected no communication with lamp power
supply
Calla qualified service engineer
2506 Lampignition failed
• hotrestrike
• lampwithman ystrikes
• maximumruntime exceeded
• Letcooldown the lamp for at
least3 minutes.
• Replacethelamp with a ne w
one
Ifproblem persists, call a qualified
service engineer
5001 DMDt emperature
• temperatureof one or more
DMD’sistoohigh
• temperatureof one or more
DMD’sis too low
Let cool down the projector. If it
persists, call a qualified service
engineer
1102 Lampinsertion not OK
• Lampnot fully inserted
• Screwsnotfully tightened
• Checkthelamp insertion
• Tightenthescrews
4004 SMPSEEPROM corrupt
•noEEPROMonSMPS
• Wrongprogrammed
EEPROMon SMPS
Downloadcorrect software
4108 GroupFan1voltagetoolow Call a qualified service engineer
4109 GroupFan2voltagetoolow Call a qualified service engineer
4110 GroupFan3voltagetoolow Call a qualified service engineer
R5976654 SLM R12+ 27/01/2005 147