Bard P1224A2 General Instructions, Shipping Damage, Field Installed Heater Packages Optional

Models: P1124A3 P1224A2

1 35
Download 35 pages 44.44 Kb
Page 4
Image 4

GENERAL INSTRUCTIONS

IMPORTANT

The equipment covered in this manual is to be installed by trained, experienced service and installation technicians. All duct work, supply and return ducts, must be properly sized for the design air flow requirement of the equipment. ACCA is an excellent guide to proper sizing. All duct work or portions thereof not in the conditioned space should be properly insulated in order to both conserve energy and prevent condensation or moisture damage.

SHIPPING DAMAGE

Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent.

FIELD INSTALLED HEATER PACKAGES (OPTIONAL)

These packaged air conditions are manufactured without supplementary electric heaters. Supplementary heaters are available for simple, fast field installation.

A separate power circuit is required for the supplementary heaters.

IMPORTANT: Refer to Table 1 when designing duct work for maximum available static pressure with heater installed.

Refer to data shown in Table 3 and 4 for proper application information on all available heater combinations and what units they can be used with. It also shows the applicable circuit ampacities, fuse size, and wire size for each heater combination.

GENERAL

The refrigerant system is completely assembled and charged. All internal wiring is complete.

The unit is designed for use with or without duct work. Flanges are provided for attaching the supply and return ducts.

These instructions explain the recommended method to install the air cooled self-contained unit and the electrical wiring connections to the unit.

These instructions and any instructions packaged with any separate equipment required to make up the entire heat pump system should be carefully read before beginning the installation. Note particularly “Starting Procedure” and any tags and/or labels attached to the equipment.

While these instructions are intended as a general recommended guide, they do not supersede any national and/or local codes in any way. Authorities having jurisdiction should be consulted before the installation is made.

TABLE 1

RATED CFM AND EXTERNAL STATIC PRESSURE

(ESP)

Model

Rated

Recommended

Rated

Max.

No.

CFM

Airflow Range

ESP

ESP

 

 

 

 

 

 

P1124A3

800

720

- 880

0.20

0.50

 

 

 

 

 

P1224A2

800

Note 1

0.10

0.50

 

 

 

 

 

 

P1130A2

1125

1020

- 1275

0.20

0.50

 

 

 

 

 

P1230A1

1000

Note 1

0.15

0.50

 

 

 

 

 

 

P1136A2

1250

1150

- 1400

0.30

0.50

 

 

 

 

 

P1236A1

1100

Note 1

0.15

0.50

 

 

 

 

 

P1142A3

1400

1260 - 1540

0.20

0.40

P1242A1

1400

Note 1

0.20

0.50

 

 

 

 

 

 

P1148A2

1550

1400

- 1700

0.40

0.50

 

 

 

 

 

P1248A2

1550

Note 1

0.20

0.50

 

 

 

 

 

 

P1060A1

1700

1530

- 1870

0.20

0.50

 

 

 

 

 

 

NOTE: ECM motors provide rated CFM up to 0.50 ESP

Manual 2100-353 Page 2

Page 4
Image 4
Bard P1224A2, P1124A3 General Instructions, Shipping Damage, Field Installed Heater Packages Optional