Bard W12A Air Conditioning Model Nomenclature, W 12 A, A 0Z, X X X X X J, Ventilation Options

Models: W12A

1 8
Download 8 pages 3.75 Kb
Page 8
Image 8
Air Conditioning Model Nomenclature

Air Conditioning Model Nomenclature

W 12 A 2

 

A 0Z

 

X X X X X J

MODEL

 

 

 

 

 

 

 

 

 

 

 

NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTS & PHASE

KW

 

 

 

 

 

A - 230/208-60-1

0Z - No KW 1

CAPACITY

 

 

 

 

 

03

- 3.6 KW 1

12 - 1 Ton

 

 

 

 

 

05

- 5.0 KW 1

 

 

 

 

 

K - 115-60-1

00

- No KW

 

 

 

 

 

 

 

 

02

- 2.2 KW

AIR CONDITIONER

REVISION

 

 

 

 

 

 

 

 

 

 

 

 

 

VENTILATION OPTIONS

(See Vent Options Below.)

COLOR OPTIONS

X-Beige (Standard)

1 - White

4 - Buckeye Gray

5 - Desert Brown

8 - Dark Bronze

FILTER OPTIONS

X- 1-Inch Throwaway - 10 x 20 x 1 W - 1-Inch Washable - 10 x 20 x 1

P - 2-Inch Pleated - 10 x 20 x 2 (MERV 8)

W 12 A 2 CONTROL MODULES (See chart below)

COIL OPTIONS

X - Standard

1 - Phenolic Coated Evaporator

2 - Phenolic Coated Condenser

3 - Phenolic Coated Evaporator

and Condenser

OUTLET OPTIONS X - Front (Standard)

1Internal circuit breakers are standard on -A models.

Clearances Required for Service Access and Adequate Condenser Inlet Airflow

MODEL

LEFT SIDE

RIGHT SIDE

W12A

15"

20"

 

 

 

NOTE: For side by side installation of two (2) W**A models there must be 20" between units.

Minimum Clearances Required to Combustible Materials

MODEL

SUPPLY AIR DUCT

CABINET

FIRST THREE FEET

 

 

W12A

0"

0"

 

 

 

Ventilation Options

Model

W12A

 

Description

Factory Installed

 

Field Installed

Code No.

 

Part No.

 

 

Barometric Fresh Air Damper - Standard

X

 

BFAD-1

 

 

 

 

Blank-Off Plate

B

 

BOP-1A

Commercial Ventilator - Spring Return w/Exhaust

V

 

CRVS-1

 

 

 

 

Economizer - Fully Modulating 1

E

 

EIFM-1B

 

 

 

 

1Low ambient control is required with economizer for low temperature compressor operation.

Air Conditioning Control Modules

All Models Except As Noted

HPC 1

LPC 2

CCM 3

LAC 4

ALR 5

Factory Installed Code

Field Installed Part

STD

STD

STD

 

 

X

N/A

STD

STD

STD

￿

 

E

CMA-28

STD

STD

STD

￿

￿

J

Factory Only

STD = Standard equipment for these specified models.

1 HPC High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3. 2 LPC Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.

3CCM Compressor control module has adjustable 30-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay- on-make will be 2 minutes plus 10% of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with 1 retry) for high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control.

4 LAC Low ambient control permits cooling operation down to 0°F.

5 ALR The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.

Bard Manufacturing Company, Inc. Bryan, Ohio 43506

www.bardhvac.com

Manufactured under U.S. Patent No. 5,301,744

Other Patents pending.

Due to our continuous product improvement policy, all specifications subject to change without notice.

Before purchasing this appliance, read important

energy cost and efficiency information available from your retailer.

Form No.

S3401

August, 2012

Supersedes S3401-510

Form No.

S3401-812

Supersedes

S3401-510

Page

8 of 8

Page 8
Image 8
Bard W12A manual Air Conditioning Model Nomenclature, W 12 A, A 0Z, X X X X X J, Ventilation Options