Air Conditioning Model Nomenclature
W 12 A 2 |
| A 0Z |
|
X X X X X J
MODEL |
|
|
|
|
|
|
|
|
|
|
| |
NUMBER |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| VOLTS & PHASE | KW | ||||||
|
|
|
|
| A - | 0Z - No KW 1 | ||||||
CAPACITY |
|
|
|
|
| 03 | - 3.6 KW 1 | |||||
12 - 1 Ton |
|
|
|
|
| 05 | - 5.0 KW 1 | |||||
|
|
|
|
| K - | 00 | - No KW | |||||
|
|
|
|
|
|
|
| 02 | - 2.2 KW | |||
AIR CONDITIONER | REVISION | |||||||||||
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
VENTILATION OPTIONS
(See Vent Options Below.)
COLOR OPTIONS
X
1 - White
4 - Buckeye Gray
5 - Desert Brown
8 - Dark Bronze
FILTER OPTIONS
X-
P -
CONTROL MODULES (See chart below)
COIL OPTIONS
X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator
and Condenser
OUTLET OPTIONS X - Front (Standard)
1Internal circuit breakers are standard on
Clearances Required for Service Access and Adequate Condenser Inlet Airflow
MODEL | LEFT SIDE | RIGHT SIDE |
W12A | 15" | 20" |
|
|
|
NOTE: For side by side installation of two (2) W**A models there must be 20" between units.
Minimum Clearances Required to Combustible Materials
MODEL | SUPPLY AIR DUCT | CABINET | |
FIRST THREE FEET | |||
|
| ||
W12A | 0" | 0" | |
|
|
|
Ventilation Options
Model | W12A |
| |
Description | Factory Installed |
| Field Installed |
Code No. |
| Part No. | |
|
| ||
Barometric Fresh Air Damper - Standard | X |
| |
|
|
|
|
B |
| ||
Commercial Ventilator - Spring Return w/Exhaust | V |
| |
|
|
|
|
Economizer - Fully Modulating 1 | E |
| |
|
|
|
|
1Low ambient control is required with economizer for low temperature compressor operation.
Air Conditioning Control Modules | All Models Except As Noted | |||||
HPC 1 | LPC 2 | CCM 3 | LAC 4 | ALR 5 | Factory Installed Code | Field Installed Part |
STD | STD | STD |
|
| X | N/A |
STD | STD | STD |
| E | ||
STD | STD | STD | J | Factory Only |
STD = Standard equipment for these specified models.
1 HPC High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3. 2 LPC Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
3CCM Compressor control module has adjustable
4 LAC Low ambient control permits cooling operation down to 0°F.
5 ALR The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.
Bard Manufacturing Company, Inc. Bryan, Ohio 43506
www.bardhvac.com
Manufactured under U.S. Patent No. 5,301,744
Other Patents pending.
Due to our continuous product improvement policy, all specifications subject to change without notice.