Baxi Potterton Cold HE A warranty Care of the Boiler, Table of Error Codes, Fault Indication

Models: Cold HE A

1 12
Download 12 pages 34.76 Kb
Page 8
Image 8

Reset

2

1 3

0 4

bar

Display

Then

Fig. 5

Table of Error Codes

E20 Central Heating NTC Fault

E28 Flue NTC Fault

E50 Hot Water NTC Fault

E110 Safety Thermostat Operated

E119 Water Pressure Switch Not Operated

E125 Circulation Fault (Primary Circuit)

E130 Flue NTC Operated

E133 Interruption Of Gas Supply or Flame Failure

E160 Fan or Fan Wiring Fault

3 4 5 PM 7

8

9

0 1

11

2

12

1

1

12

2

11

0

3

1 0

9

8

7

A

M

5 4

5.0Care of the Boiler

5.1Cleaning the Outer case

The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS.

5.2Protection & Precaution

1.The boiler incorporates an integral frost protection feature that will operate in both modes. If the boiler temperature falls below 5° C, then the boiler will operate until the water temperature has been raised.

2.If a system frost thermostat has been fitted (your installer will be able to advise you), then to operate correctly and protect your system, the gas and electricity must be left on and the appliance set in the central heating mode.

3.The boiler incorporates an integral pump protection feature which continually monitors the time since the pump last operated. To prevent seizure, the pump will operate for approximately 1 minute if it has not run in the last 24 hours.

5.3Fault Indication

1.If a fault occurs on the boiler an error code may be shown on the facia display (Fig. 5).

2.The codes are either two or three digit, preceded by the letter 'E'. For example, code E133 will be displayed by 'E1' alternating with '33'. E50 is shown as 'E' then '50'.

3.E20, E28, E50, E125 & E160 indicate faulty components. You should make a note of the displayed error code and contact your installer or service engineer.

4.If E110 or E130 is displayed overheat of the primary water or flue system has occurred. Turn the selector switch to the reset position and hold for at least 5 seconds. If the boiler does not relight, or the code is displayed regularly contact your installer or service engineer.

5.E119 is displayed when the primary water pressure is less than 0.5 bar. After repressurising the system the boiler should operate. Your installer will be able to advise you about the method of repressurising. See page 6 for further details.

6.E133 indicates that the gas supply has been interrupted, ignition has failed or the flame has not been detected. Ensure that the gas supply has not been turned off, and turn the selector switch to the reset position and hold for at least 5 seconds. If the boiler does not relight, or the code is displayed regularly contact your installer or service engineer.

8© Baxi Heating UK Ltd 2008

Page 8
Image 8
Baxi Potterton Cold HE A warranty Care of the Boiler, Table of Error Codes, Fault Indication

Cold HE A specifications

The Baxi Potterton Cold HE A is a highly efficient and reliable gas boiler, designed to meet the increasing demands for energy-efficient heating solutions in domestic settings. Known for its compact design and advanced technology, this boiler stands out as an excellent choice for homeowners looking to lower their energy bills while still enjoying consistent warmth throughout their homes.

One of the main features of the Baxi Potterton Cold HE A is its high efficiency rating. With an impressive Energy Efficiency Index, this boiler operates using a condensing technology that captures heat from the exhaust gases, recycling it to provide additional heating. This significantly reduces overall energy consumption, making it an environmentally friendly option while also cutting down utility costs.

Installation flexibility is another key characteristic of the Baxi Potterton Cold HE A. Its compact size allows it to be installed in a variety of locations within the home, from kitchen cupboards to utility rooms. This versatility ensures that homeowners can integrate the boiler seamlessly into their living space without compromising on aesthetics.

The Baxi Potterton Cold HE A also benefits from a user-friendly digital control interface, which empowers homeowners to easily adjust settings and monitor heating performance. This intuitive control system allows for precise temperature settings and scheduling, ensuring that the home remains comfortable without unnecessary heating when it is not required.

In terms of safety, this boiler is equipped with various safety features. It has a built-in frost protection system to prevent freezing during colder months and a comprehensive flue gas analysis system to ensure efficient operation and reduced emissions. Additionally, the unit is designed with easy maintenance in mind; components are easily accessible, simplifying servicing and reducing downtime.

Moreover, the Baxi Potterton Cold HE A is backed by a robust warranty, reflecting the manufacturer's confidence in the durability and longevity of the product. Users can enjoy peace of mind knowing that they are investing in a boiler that is built to last and supported by reliable customer service.

In summary, the Baxi Potterton Cold HE A is an exemplary gas boiler that combines high efficiency, installation flexibility, user-friendly controls, safety features, and excellent reliability, making it a sensible choice for any modern household looking to enhance their heating system.