SPECIFICATIONS

Frequency

process mode

Program controlled

 

 

Response

bypass mode

10Hz to 50kHz +/-0.5dBu, -10dBu input

 

 

 

 

 

 

 

 

process mode

less than 0.025% at -10dBu input, 20-20kHz

THD

 

 

bypass mode

less than 0.002% at -l0dBu input, 20-20kHz

 

 

 

 

 

 

Maximum Output

+18dBu (may vary due to control settings)

 

 

 

Input Impedance

47k Ohms, unbalanced 1/4” phone jack or RCA jack

 

 

 

Output Impedance

1k Ohms, unbalanced 1/4” phone jack or RCA jack

 

 

 

 

Sensitivity

 

-45dBu for maximum process

 

 

 

Maximum Process

+12dBu boost at 5kHz, -10dBu input

 

 

 

 

Lo Contour

 

+12dBu boost at 50Hz, -10dBu input

 

 

 

 

 

 

U.S., Canada

100-120VAC, 50/60Hz, 8 WATTS

 

 

and Japan

 

Power

 

models

 

Requirements

 

 

 

 

220-240

220-240VAC, 50/60Hz, 8 WATTS

 

 

 

 

models

 

 

 

 

 

Fuse

 

For all models, replace with 250VAC, .2A slowblow type

 

 

 

fuse.

 

 

 

Dimensions

 

19”(W) x 5.5”(D) x 1.7”(H)

 

 

Shipping Weight

6.5 lbs.

 

 

 

 

* 0dBu = 0.775mVrms

Note: Due to continuing product improvement, specifications and design are subject to change without notice.