SPECIFICATIONS

Frequency

process mode

Program controlled

 

 

Response

bypass mode

10Hz to 50kHz +/-0.5dBu, 0dBu input

 

 

 

 

 

 

 

 

process mode

less than 0.025% at -10dBu input, 20-20kHz

THD

 

 

bypass mode

less than 0.002% at -l0dBu input, 20-20kHz

 

 

 

 

 

 

Maximum Output

+23dBu (may vary due to control settings)

 

 

 

 

Input Impedance

14.7k Ohms, balanced 1/4” TRS phone jack or

XLR jack Pin #2 hot or “+”

 

 

 

 

 

 

 

Output Impedance

600 Ohms, balanced 1/4” TRS phone jack or

XLR jack Pin #2 hot or “+”

 

 

 

 

 

 

 

Sensitivity

 

-45dBu for maximum process

 

 

 

Maximum Process

+12dBu boost at 5kHz, 0dBu input

 

 

 

 

Lo Contour

 

+12dBu boost at 50Hz, 0dBu input

 

 

 

 

 

 

U.S., Canada and

100-120VAC, 50/60Hz, 8 WATTS

Power

 

Japan models

 

Requirements

 

 

 

 

220-240 models

220-240VAC, 50/60Hz, 8 WATTS

 

 

 

 

 

 

Fuse

 

For all models, replace with 250VAC,

 

.2A slowblow type fuse.

 

 

 

 

 

 

Dimensions

 

19”(W) x 5.5”(D) x 1.7”(H)

 

 

Shipping Weight

6.5 lbs.

 

 

 

 

* 0dBu = 0.775mVrms

Note: Due to continuing product improvement, specifications and design are subject to change without notice.