GREEN | WHITE | YELLOW | BLUE | BROWN | |
SWING | ACT. | COM . | SAF. | STALL | STAL COM . |
BESAM 300 | 13 | 12 | 11 | 15, 17 | 16,18 |
BESAM M/P | 3 | 4 | 9 | 5 | 13 |
DOM | YELLOW | GREY | BLUE | PURPLE | GREY |
GT 300/400 | BLACK | RED | WHITE | WHITE | RED |
GT MAG | 6 BLACK | 5 RED | 4 WHITE | 3 VIOLET | 5 RED |
HORTON 4190 | 2 | 3, 6, 8 | 4 | 10 | 3, 6, 8 |
HUNTER | ACT. | RTN | SAF. 1 | SAF. 2 | RTN |
KM K | GREEN | WHITE | RED | YELLOW | WHITE |
STANLEY "L" | ORANGE | YELLOW | RED | BLUE | YELLOW |
STANLEY M/P | 2 | 1, 8 | 7 | 7 | 1, 8 |
STANLEY 521 | |||||
TORMAX TDA | 2 | 1 ,3, 6, 8 | 8 & 9 | 7 | 1, 3, 6, 8 |
DC | + | RED | |
MOTOR | - | RED |
|
SEE NOTE # 1
EAGLE 1
|
|
|
|
|
|
|
|
| RED | BLACK | WHITE | GREEN | |||
|
|
|
|
|
|
|
|
EAGLE 2
RED | BLACK | WHITE | GREEN | SEE NOTE # 4 |
75.5137.02 |
|
|
|
|
|
|
|
|
|
|
|
| BLACK | 24 V |
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
MTR |
| STALL |
|
| SENSORS |
| AUX |
|
|
|
|
|
|
| RED | TRANSFORMER |
| |||
|
|
|
|
|
|
| TO CTRL |
|
|
|
|
|
|
| ||||||
MOTOR | STALL1 | STALL2 |
| EAGLE1 | EAGLE2 | MTDDOOR SENSOR1 MTDDOOR SENSOR2 | BODY- GUARD | N/O | COM | BEAM | SWITCH | PWR | SETUP |
| BLACK |
| ||||
| TX RX | HOLD AUTO GND | ACTIV. SAFETY STALL COMACT/SFTY COMSTALL | AC/DC | INCR. FUNCT. |
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| switch | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| assembly | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RED | AUTO |
|
|
|
|
|
|
| HARNESSp/n: 20.5082 |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| SEE NOTE #3 |
|
|
|
|
|
| 1 IN |
| OFF | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OFF |
|
|
|
|
|
|
|
|
|
| N/O | COM |
|
|
|
|
|
|
| WHITE |
|
|
|
|
|
|
|
|
|
|
|
|
| HOLD OPEN | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
| SEE NOTE |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| # 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| HARNESS p/n: 20.5097 |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 GND |
| AUTO |
|
|
|
|
|
|
|
|
| * |
|
|
|
|
|
|
|
| 3 IN |
| OPEN |
|
|
|
|
|
|
|
|
| BODYGUARD (Y) HARNESS |
|
|
| WHITE | 4 GND |
|
| ||||
|
|
|
|
|
|
|
|
| USED FOR |
|
|
| GREEN |
| ACT. | |||||
|
|
|
|
|
|
|
|
| APPLICATIONS |
|
|
|
|
| 5 IN |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6 24+ |
|
|
|
|
|
| SEE NOTE # 4 |
|
|
|
|
|
| SEE NOTE # 4 |
| 7 GND |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8 IN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 9 OUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 10 24+ |
| DOOR |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 11 OUT |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 12 24V+V | STATUS | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BLUE | 13 GND | SWING | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 14 IN | |||
RED | BLACK | WHITE | GREEN |
| BROWN | BLUE |
|
|
| RED | BLACK | WHITE | GREEN | BROWN | BLUE |
| BROWN | |||
|
|
|
|
| 17 GND | SIDE SAFETY | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 15 OUT | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| YELLOW | 18 IN | BODYGUARD | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| 19 OUT | SAFETY | |||||||||
|
|
|
|
|
|
|
|
| 20 +24V |
|
| |||||||||
p/n: 70.5071 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GREEN | WHITE | BLACK | RED |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
EMPTY | INHIBITGND | INHIBIT+ | N.C. | N.O. | COM | POWER | POWER |
|
|
|
| GREEN | WHITE | BLACK | RED |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
EMPTY | INHIBITGND | INHIBIT+ | N.C. | N.O. | COM | POWER | POWER |
|
|
|
| GREEN | WHITE | BLACK | RED |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
EMPTY | INHIBITGND | INHIBIT+ | N.C. | N.O. | COM | POWER | POWER |
|
|
|
| GREEN | WHITE | BLACK | RED |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
EMPTY | INHIBITGND | INHIBIT+ | N.C. | N.O. | COM | POWER | POWER |
DOOR MTD SENSOR |
|
|
| DOOR MTD SENSOR |
|
|
| DOOR MTD SENSOR |
|
|
APPROACH SIDE |
|
|
| SAFETY SIDE |
|
|
| APPROACH SIDE |
|
NOTES:
1.MOTOR CONNECTION IS TIED IN PARALLEL TO EXISTING MOTOR LEADS. NO RESPECT TO PALARITY IS REQUIRED.
2.EXTERNAL SWITCHES ARE REQUIRED IF INHIBIT DESIRED AT SWING SIDE SUPERSCANS, SWITCH OPENS UPON INHIBIT POINT.
3.THE KNOWING ACT SWITCH IS CONNECTED AT THE AUX INPUT AND CAN BE ANY DRY CONTACT DEVICE SUCH AS A PUSHPLATE, CARD READER, ETC. THE AUX INPUT IS REQUIRED FOR ALL INITIAL ACTIVATION WHEN FUNCTION 'FA' ON THE
4.THE SECOND BODYGUARD AND EAGLE ARE PRIMARILY USED IN
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC. FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT
DOOR MTD SENSOR
SAFETY SIDE
100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412)
TITLE: TORMAX-TTXII LO-LINX SYSTEM
| DRAWN BY: | REV BY: | PART NO: | |
SIZE: | 80.0289.00 | |||
JED | TUC | |||
|
|
| ||
A | SCALE: | DATE: | SHEET | |
| NONE | 10/15/2007 | 1 OF 1 |