SIZE: DRAWN BY:
TITLE: STANLEY DURAGLIDE WITH
WIZARD II SYSTEM, MICROCELL
A
100 ENTERPRISE DRIVE
PITTSBURGH, PA 15275
PHONE: (412) 249-4100
FAX: (412) 249-4101
EMAIL: www.beasensors.com
REV BY:
KJG TUC 80.0123.04
SCALE: DATE:
NONE 24 NOV 2005
PART NO:
SHEET
1 OF 1
EXTERIOR WIZARD

24 V

TRANSFORMER
INTERIOR WIZARD
NOTES: 1) WIZARDS WILL OPERATE WITH THE 12 VDC ON PINS 1&2, 5&6.
2) ONE WAY FUNCTION IS APPLICABLE IF CLOSED DOOR MONITORING SWITCH IS INSTALLED.
SWITCH SHALL CLOSE 2" FORM FULL CLOSE

TB- 2

1
2
3
4
5
6
7
8
TB- 3
1
2
3
4
5
6
7
8HOLDING
BEAMS
COMMON
EXTERIOR SCAN
INTERIOR SCAN
COMMON
DURAGLIDE INTERFACE BOARD
COMMON
RA WH 1
RA BL 2
EA WH 3
EA BL 4 5 NC
4 NO
3 COM
2 12-24 VAC/DC
1 12-24 VAC/DC
RB WH 1
RB BL 2
EB WH 3
EB BL 4
* RECEIVER (A), EMITTER (A)
RECEIVER (B), EMITTER(B)
WH= WHITE, BL= BLACK
MICROCELL ONE
ON
1 2 3 4
RA WH 1
RA BL 2
EA WH 3
EA BL 4 5 NC
4 NO
3 COM
2 12-24 VAC/DC
1 12-24 VAC/DC
RB WH 1
RB BL 2
EB WH 3
EB BL 4
* RECEIVER (A), EMITTER (A)
RECEIVER (B), EMITTER(B)
WH= WHITE, BL= BLACK
MICROCELL ONE
ON
1 2 3 4
IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC.
FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS,
CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT
LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE
DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE
AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM

SEE NOTE 2