1 Description / Specifications

FACE PLATE (DOUBLE SIDED TAPE MOUNTED TO PLATE)

SELF-DRILLING MOUNTING SCREWS (2)

TOGGLE SWITCH

(WIRING HARNESS NOT SHOWN)

DOORSWITCH

USER’S GUIDE

TOGGLE SWITCH

DESCRIPTION

SPECIFICATION

DIMENSIONS

2.50” (64mm) L

 

1.50” (38mm) H

 

1.75” (44mm) D

MATERIAL

Anodized Aluminum

SWITCH RATING

10A 125VAC

 

6A 250VAC

 

On-Off-On

2Precautions

‰Shut off all power in access control circuit before attempting any wiring procedures.

‰Maintain a clean & safe environment when working in public areas.

‰Constantly be aware of pedestrian traffic around the door area.

‰Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

‰ESD electrostatic discharge: Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board ensure you dissipate your body’s charge.

‰Always check placement of all wiring before powering up to insure that moving door parts will not catch any wires and cause damage to equipment.

‰Ensure compliance with all applicable safety standards (i.e. ANSI A156.10/19) upon completion of installation.

‰DO NOT attempt any internal repair of the Piezo Button. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair:

1.May jeopardize personal safety and may expose one to the risk of electrical shock.

2.May adversely affect the safe and reliable performance of the product will result in a voided product warranty.

3 Installation

20.5078 HOLD SWITCH

NOTE: Cut-off connector ONLY if wiring directly to operator.

DOOR SWITCH

DOOR CONTROL

ON

1a

RED

COMMON

 

BLACK

 

OFF

1

ACTIVATION

 

WHITE

 

HOLD

1b

SAFETY

OPEN

 

 

1.

The Doorswitch is designed to be a plug-and-go connection to the LO-Llinx modules.

ACTIVATING

DEVICES

 

 

2.

If the Doorswitch is to be wired to a door that is NOT using the LO-Linx module,

 

 

cut off the connector, strip the wires and wire as shown above.

 

4 Company Contact

Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the following workday to call BEA, leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.

The following numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com.

US and Canada: 1-866-249-7937

Southeast: 1-800-407-4545

Canada: 1-866-836-1863

Midwest:

1-888-308-8843

Northeast: 1-866-836-1863

West:

1-888-419-2564

75.5189.01 20071101

 

Page 1 of 1

Page 1
Image 1
BEA Door Switch And Toggle Switch specifications Description / Specifications, Precautions, Installation, Company Contact

Door Switch And Toggle Switch specifications

BEA door switches and toggle switches are essential components in various applications, particularly in automation, security, and access control systems. They serve critical roles in ensuring efficient and safe operations in both residential and commercial environments. Each type of switch has its unique features, technologies, and characteristics that make them suitable for specific tasks.

BEA door switches are primarily designed for use in automatic doors, providing a reliable way to detect the presence of individuals or objects. These switches utilize advanced sensing technologies, including infrared, pressure, and radar sensors. The infrared models are particularly popular for their ability to detect movement in real-time, ensuring that doors open only when someone is present. Pressure-sensitive switches, on the other hand, are embedded in mats or thresholds to activate doors when weight is applied, making them ideal for high-traffic areas. Radar sensors offer the advantage of detecting motion through various materials, allowing for versatile placements without compromising performance.

A standout feature of BEA door switches is their durability. They are constructed to withstand harsh environmental conditions, including extreme temperatures, humidity, and exposure to chemicals, ensuring long-lasting functionality. Many models also feature customizable sensitivity settings and adjustable activation ranges, allowing for optimized performance in different scenarios.

Toggle switches, in contrast, are more straightforward in design but equally versatile. They are commonly used in control panels and are favored for their simplicity and reliability. Toggle switches can be mechanical or electronic, with the former utilizing a physical lever that mechanically connects or disconnects the circuit. Electronic toggles offer enhanced control features, such as different operational modes or momentary switches, allowing for more complex applications.

The primary advantage of toggle switches is their tactile feedback, which provides a clear indication of the switch's position. They can be found in various configurations, including single-pole, double-pole, and multi-position varieties, making them suitable for a wide range of applications, from lighting fixtures to machinery controls.

In summary, BEA door switches and toggle switches are vital components that enhance automation and control in many systems. With advanced sensing technologies, durability, and versatility, BEA door switches cater to the needs of automated entry solutions, while toggle switches provide simple yet effective control options for numerous applications. Understanding their features and characteristics helps users choose the right switch for their specific requirements, ensuring optimal performance and safety in operation.