BEA Door Switch And Toggle Switch specifications Doorswitch, Description / Specifications, Common

Models: Door Switch And Toggle Switch

1 1
Download 1 pages 55.56 Kb
Page 1
Image 1
1 Description / Specifications

1 Description / Specifications

FACE PLATE (DOUBLE SIDED TAPE MOUNTED TO PLATE)

SELF-DRILLING MOUNTING SCREWS (2)

TOGGLE SWITCH DOORSWITCH

(WIRING HARNESS NOT SHOWN)

DOORSWITCH

USER’S GUIDE

TOGGLE SWITCH

DESCRIPTIONSPECIFICATION

DIMENSIONS

2.50” (64mm) L

 

1.50” (38mm) H

 

1.75” (44mm) D

MATERIAL

Anodized Aluminum

SWITCH RATING

10A 125VAC

 

6A 250VAC

 

On-Off-On

2Precautions

‰Shut off all power in access control circuit before attempting any wiring procedures.

‰Maintain a clean & safe environment when working in public areas.

‰Constantly be aware of pedestrian traffic around the door area.

‰Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

‰ESD electrostatic discharge: Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board ensure you dissipate your body’s charge.

‰Always check placement of all wiring before powering up to insure that moving door parts will not catch any wires and cause damage to equipment.

‰Ensure compliance with all applicable safety standards (i.e. ANSI A156.10/19) upon completion of installation.

‰DO NOT attempt any internal repair of the Piezo Button. All repairs and/or component replacements must be performed by BEA, Inc. Unauthorized disassembly or repair:

1.May jeopardize personal safety and may expose one to the risk of electrical shock.

2.May adversely affect the safe and reliable performance of the product will result in a voided product warranty.

3 Installation

20.5078 HOLD SWITCH

NOTE: Cut-off connector ONLY if wiring directly to operator.

DOOR SWITCH

DOOR CONTROL

ON

1a

RED

COMMON

 

BLACK

 

OFF

1

ACTIVATION

 

WHITE

 

HOLD

1b

SAFETY

OPEN

 

 

1.

The Doorswitch is designed to be a plug-and-go connection to the LO-Llinx modules.

ACTIVATING
DEVICES

 

 

2.

If the Doorswitch is to be wired to a door that is NOT using the LO-Linx module,

 

 

cut off the connector, strip the wires and wire as shown above.

 

4 Company Contact

Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the following workday to call BEA, leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.

The following numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com.

US and Canada: 1-866-249-7937Southeast: 1-800-407-4545
Canada: 1-866-836-1863Midwest:

1-888-308-8843

Northeast: 1-866-836-1863West:

1-888-419-2564

75.5189.01 20071101

 

Page 1 of 1
Page 1