ADCOil Burner 12v or 24v
Description
The Beckett ADC Oil Burner is designed for applications where an AC power source is not an option. Available in 12V and 24V configurations, the ADC burner is conveniently powered by a standard direct
current power supply.
Features & Benefits
•Available in either 12Vdc or 24Vdc configurations
•Beckett GeniSys Control uses a suitable cad cell flame sensor to control the motor, igniter, and solenoid valve.
•Interrupted duty ignition extends battery life by only drawing full load current during the ignition period. Intermittent duty ignition is also available.
•Beckett CleanCut Pump has an integrated solenoid valve for smoother
•Air Guide provides high static pressure for smooth starts and minimal pulsation.
Specifications
Rated Voltage: 13.5V or 27V (Nominal Charging System Voltage)
Reference Voltage: 12V or 24V (Battery Discharge Voltage)
Capacity at Rated Voltage
▫0.75 - 3.00 GPH
▫105,000 - 420,000 Btu/h
Capacity at Reference Voltage
▫0.75 - 2.50 GPH
▫105,000 - 350,000 Btu/h
Fuels
▫No.1 or No.2 heating oil (ASTM D396) only
Dimensions
▫Height:
▫Width:
▫Depth:
Ambient Operating Temperature
▫Min: +32°F (0°C)
▫Max: +115°F (46°C)
Electrical Ratings
Power Supply | 13.5Vdc | 27Vdc |
|
|
|
Voltage range | 11V - 16V | 21.6V - 28V |
Operating Load | 15A max. | 10A max. |
|
|
|
w/ igniter off | 8 - 10 Amps | |
Motor Voltage, nominal | 13.5V | 27V |
|
|
|
Full load amps | 12.1A max. | 6.1A max. |
|
|
|
Locked rotor amps | 100A | 50A |
|
|
|
Flame Retention Heads (see reverse)
▫F3: 0.75 - 1.25 GPH
▫F6: 0.85 - 1.65 GPH
▫F12: 1.10 - 2.00 GPH
▫F16: 1.50 - 2.25 GPH
▫F22: 1.65 - 2.50 GPH
▫F31: 2.50 - 3.00 GPH