16. Generally, what is the typical operation of the AquaSmart?

16. Generally, what is the typical operation of the AquaSmart?

Following are typical responses to a variety of system actions.

System Action

AquaSmart Response

 

 

Maintaining the Low Limit

Burner is turned on until the water temperature reaches the low limit plus the low differential.

ZC is turned off until the water temperature reaches the low limit plus the low differential

 

 

 

Thermostat Call for Heat

Burner is turned on as long as the water temperature is below the high limit. Circulator is

turned on after circulator-on delay if the low limit is satisfied.

 

 

 

Thermostat is Satisfied

Burner is turned off

Circulator is turned off after circulator-off delay

 

 

 

ZR Call for Heat

Burner is turned on as long as the water temperature is below the high limit.

 

 

ZR is Satisfied

Burner is turned off.

 

 

Maintaining the High Limit

Burner is turned off until the water temperature falls below the high limit minus the high

differential.

 

 

 

17. How can I be sure that I have installed the AquaSmart correctly?

When you have completed the installation of the unit you will go through the Control Checkout Procedure.

These procedures are typical for the default configuration of the control. Before beginning the AquaSmart checkout procedure, make sure the control is wired and configured as is required by the application. You will find the steps for the check out procedure in the AquaSmart Information and Operation Manual.

CAUTION! Do not leave the installation site if the AquaSmart operation did not match the descriptions in any of the steps in the checkout procedure. Make all necessary adjustments until the correct operation is verified. The checkout procedure helps to verify that the high and low limits are working properly and that the thermostat is wired correctly to the control.

18. Does the AquaSmart provide any other Benefits?

Yes, there are benefits provided in several different areas.

The homeowner should know that in a short period of time the AquaSmart will pay for itself when the HeatManager is enabled. That’s right. Due to the up to 20% energy savings from our energy efficient features the homeowner will realize up to $300 sav- ings per year in a typical home. With conserving energy and saving money the AquaSmart is precisely what consumer is looking for.

Additionally, the homeowner benefits from increased comfort and peace of mind. The AquaSmart will give priority to a call for Domestic Hot Water. This helps to ensure a steady supply of hot water to the home. The AquaSmart will also give the homeowner added peace of mind due to its automatic freeze-up resistance feature.

Our Environment definitely Benefits with the AquaSmart. Did you know that if every Boiler in the United States used the AquaSmart control it would reduce our nation’s fuel consumption by the equivalent of 24.6 million barrels of fuel/year?