National Combustion CO-XC Series Boiler
Boiler Burner
Chassis
Spec.
Air Tube
Combination
High
Fire
Rate Nozzle
Head
Setting
Blue -
Low Fire
Air or
Shutter
Red -
High Fire
Air or
Band
Low Fire
Pump
Press.
High Fire
Pump
Press.
Pressure
Firing
Flange Insertion
58 CF800 BCF403 CF60KH 4.50 4.00x45P 3 10 0 N/A 140 51311 3.00"
72 CF800 BCF403 CF60KH 5.25 4.50x45P 4 10 5 N/A 140 51311 3.00"
82 CF1400 BCF205 CF66KE 6.00 3.50x45P 1/2 20 40 150 300 51629 3.00"
105 CF1400 BCF205 CF66KE 8.00 4.50x45P 2-1/2 30 60 150 300 51629 3.00"
130 CF2300A BCF304 CF66KG 10.00 5.50x45p 0 15 30 150 300 51630 3.00"
165 CF2300A BCF304 CF66KG 12.00 7.00x45P 1 30 40 150 300 51630 3.00"
200 CF2300A BCF304 CF66KG 15.00 9.00x45P 4 25 40 150 300 51630 3.00"
250 CF2300A BCF304 CF102KS 19 .00 11.00x45P 5 35 55 150 300 51630 6.00"
290 CF2500A BCF1801 CF66KP 22.00 6.50x45P (2) 5 25 50 300 300 51630 3.00"
400 CF3500A BCF1301 CF114KR 29.90 8.50x45P (2) 5 30 80 300 300 51631 6.00"
Shutter and band settings refer to the AFG, CF375, CF500 and CF800 only.
Page 19