Burner Start Up Information & Test Data

Beckett Model ____________________ Serial Number_______________________

Job Location_____________________________________________________________

Start Up Date_____________ Company Name_________________ Technician Name________________

Type of Gas: NAT____ Propane____

Gas Pressure at Train Inlet

Flame Signal Readings

Draft @ Breech

Burner off position ______w.c

Low Fire _______DC volts

 

 

High Fire _______DC volts

High Fire_________w.c

Gas Pressure Train Inlet

O2

Net Stack Temperature

Light-Off ________w.c

Light-Off _______%

 

High Fire ________w.c

High Fire _______%

High Fire _________degrees

Gas Pressure at Burner

CO

Combustion Efficiency

Light-Off ________w.c

Light-Off _______%

 

High Fire ________w.c

High Fire _______%

High Fire _________%

Power Supply

Input Rate BTU/HR

Air Damper Settings

Volts____ PH____ Hz____

 

Shutter___________

 

High Fire_______

Band___________

Control Settings:

 

Operating Control Cut/Out

Limit Control Cut/Out Setting

Low/High Gas Pressure

 

____________________

________________________

_________/___________

 

 

Operating Control Cut/In Setting

 

Limit control Cut/In Setting

 

 

 

 

 

_______________________

_______________________

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Checked for Proper Operation

 

YES

NO

Checked for Proper Operation

YES

NO

 

 

 

 

 

 

 

 

 

 

 

Low water cut off

 

 

 

Barometric Damper

 

 

 

 

 

High water cut off

 

 

 

Boiler Room combustion air

 

 

 

 

 

Flame Safeguard control ignition failure

 

 

 

All gas lines checked for leaks

 

 

 

 

 

Flame Safeguard control main flame failure

 

 

 

Gas lines and controls properly vented

 

 

 

 

Burner air flow switch

 

 

 

Other system components specify

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notified___________________________ of the following system deficiencies__________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

_________________________________________________________________________________________

Page 4
Image 4
Beckett CG10A, CG10B manual Gas Pressure Train Inlet Net Stack Temperature, Gas Pressure at Burner Combustion Efficiency

CG10B, CG10A specifications

The Beckett CG10A and CG10B are advanced combustion systems designed for residential and commercial heating applications. These models are part of Beckett's commitment to providing efficient, reliable, and innovative solutions in the heating industry. With a focus on performance and user-friendliness, both units feature several key characteristics that set them apart from traditional burners.

At the heart of both the CG10A and CG10B models is the state-of-the-art combustion technology that ensures maximum efficiency and minimal emissions. Their design incorporates advanced air-fuel mixing systems, which enhance combustion stability and optimize fuel use. This not only results in lower energy bills for consumers but also aligns with contemporary environmental standards by reducing the carbon footprint of heating operations.

One of the main features of the CG10A is its straightforward installation process. Designed with flexibility in mind, it can be easily integrated into various heating systems, making it a versatile choice for both new and existing installations. The CG10B, meanwhile, boasts additional features such as enhanced noise reduction technology, ensuring quiet operation – a significant factor for residential applications.

Both models come equipped with an adjustable flame retention head, allowing users to customize the burner’s performance based on their specific heating needs. This feature contributes to the overall efficiency of the system, providing consistent heat output while minimizing the risk of overheating or energy waste.

In terms of durability, Beckett has built the CG10A and CG10B to withstand the rigors of daily use. They are constructed from high-quality materials that resist corrosion and wear, ensuring a long lifespan. Furthermore, these burners are designed for easy maintenance, with accessible components that allow technicians to perform routine inspections and servicing with minimal effort.

The Beckett CG10A and CG10B also feature advanced safety controls, which include flame sensing and lockout mechanisms. These features are critical in preventing unsafe operating conditions, giving users peace of mind. The combination of efficiency, reliability, and safety makes these models an excellent choice for consumers seeking to upgrade their heating systems.

In conclusion, the Beckett CG10A and CG10B represent the pinnacle of burner technology, combining efficiency, ease of installation, and reliability. With their advanced features and commitment to environmental sustainability, they are poised to meet the demands of both today’s heating markets and the needs of consumers.