Beckett R7184 manual Wiring System Changes

Models: R7184

1 2
Download 2 pages 41.55 Kb
Page 2
Image 2
WIRING SYSTEM CHANGES

WIRING SYSTEM CHANGES

Beckett burners have taken advantage of the changes in the R7184 controls to improve the wiring system. Component and power cord wires, now color-coded to match the terminal colors on the control, are terminated with 0.25-inch flag terminals (QCs) to fit the spade connectors (QCs) on the control. During the time required to convert all components and controls to the new wiring system, some adaptations may be required when replacing individual components on the burner.

CHANGING COMPONENTS — When changing components, the type of connection that you need to make depends on the way the components (motor, valve, igniter), power cord and control are terminated. Where all the leads / connections are the same, no modifications are required. Where the two ends of a connection are dissimilar, see the options in the following table:

If your components are

 

You should use the following:

 

terminated like this:

 

 

 

 

 

 

 

 

 

 

Components

Control

 

Connection options

 

 

 

 

 

 

Stripped end

Wire leads

Wire nuts

 

 

 

 

 

 

Flag terminal

Spade

QC (Quick Connect)

 

 

 

 

 

 

Flag Terminal

Wire leads

Cut flag terminal and strip

 

 

end–Wire nut

 

 

 

 

 

 

 

 

 

 

 

 

Add flag terminal to component

 

 

 

 

lead– QC

 

Stripped end

Spade

Cut existing component lead 6-7

 

 

 

 

 

 

 

in. from flag terminal and strip

 

 

 

 

end–Wire nut (Fig. 1 & 2)

 

 

 

 

 

Reduced number of leads in wiring box.

 

 

 

 

Fig. 1 – Cutting lead from component to be

Fig. 2 – Using jumper to connect to new

replaced to use as jumper

component with stripped leads

Beckett Service Kits for termination conversion:

51947–Full service kit including a full complement of (6) QC pigtails (BLK, W, O, BLU, V, R), (6) wire nuts and (9) 0.25-inch flag terminals, and this instruction sheet.

51948–Termination kit including (9) 0.25-inch flag terminals, (6) wire nuts, and instruction sheet.

If you have any questions regarding controls or the Beckett R7184 primary control by Honeywell, please contact R.W. Beckett at 1-800-645-2876 or visit our web site at www.beckettcorp.com.

R.W. Beckett Corporation • P. O. Box 1289 • Elyria, Ohio 44036 • (800) 645-2876 • (440) 327-1060 • FAX (440) 327-1064

R.W. Beckett Canada Ltd. • Unit 3 - 430 Laird Road • Guelph, Ontario, Canada N1G 3X7 • (800) 665-6972 • FAX (519) 763-5656

RWB 664857R0404

Printed in U.S.A.

Page 2
Image 2
Beckett R7184 manual Wiring System Changes