ULTRACURVE PRO DEQ2496
If several devices shall be embedded into a digital recording system comprising, for example, a digital mixing console, all connected digital devices must be synchronized using a common wordclock signal. To this end, your DEQ2496 features a wordclock input, which can be used to control external equipment via wordclock signals. The input supports the sample rates 44.1, 48, 88.2 and 96 kHz, and can be activated only if the analog inputs are used.
6. OPERATING software
The operating software of your ULTRACURVE PRO DEQ2496 is constantly being developed to improve its performance and adapt the operation of the unit to user requirements. We would therefore be pleased to hear about your suggestions and ideas for improvement. We will try to include your suggestions in the next software revision. Information on new software versions are available from the trade press, your retailer, from our web site at www.behringer.com or directly from BEHRINGER (Tel. +49 2154 9206 4166).
The current software revision of your ULTRACURVE PRO DEQ2496 is displayed in the UTILITY menu on page 1 (top right).
7. SPECIFICATIONS | |
Analog inputs |
|
Type | electronically balanced |
Connector | XLR |
Impedance | 22 kΩ at 1 kHz |
Max. input level | +12 or +22 dBu, switchable |
CMRR | 40 dB typ. |
Analog outputs (main) |
|
Type | |
Connector | XLR |
Impedance | 100 Ω at 1 kHz |
Max. output level | +12 or +22 dBu, switchable |
Analog outputs (aux) |
|
Type | |
Connector | 1/4" stereo jack |
Impedance | 100 Ω at 1 kHz |
Max. output level | +12 dBu |
System specifications |
|
Frequency range | 10 Hz to 35 kHz |
| @ 96 kHz sampling rate |
> 113 dB main input/output | |
| > 107 dB aux output |
THD | 0.007 % typ. @ +4 dBu, 1 kHz, |
| unity gain |
Crosstalk | < |
Bypass |
|
Type | Relay, |
| power failure |
Measurement microphone input | |
Type | electronically balanced |
Input impedance | 2 kΩ |
Max. input level (LINE) | variable from |
Max. input level (MIC) | variable from |
| |
Phantom power | +15 V, switchable |
Digital input 1 |
|
Type | XLR |
Standard | AES/EBU or S/PDIF |
Input impedance | 110 Ω |
Nom. input level | 0.2 - 5 V |
Digital input 2 |
|
Type | TOSLINK optical |
Standard | AES/EBU or S/PDIF |
Digital output 1 |
|
Type | XLR |
Standard | AES/EBU or S/PDIF |
Impedance | 110 Ω |
Output level | 3.5 V |
Digital output 2 |
|
Type | TOSLINK optical |
Standard | AES/EBU or S/PDIF |
Sync input |
|
Type | BNC |
Standard | Wordclock (1 x sample rate) |
Input impedance | 50 kΩ |
Nom. level | 2 - 6 V |
MIDI interface |
|
Type | |
Implementation | cf. MIDI implementation chart |
Digital processing |
|
Converter | |
| |
Sample rate | 44.1, 48, 88.2, 96 kHz |
Graphic equalizer (GEQ) |
|
Type | digital |
Frequency range | 20 Hz to 20 kHz, 31 |
| according to ISO frequencies |
Bandwidth | |
Control range | +15 to |
Parametric equalizer (PEQ) |
|
Type | max. 10 independent, fully |
| parametric filters per channel |
Frequency range | 20 Hz to 20 kHz |
Bandwidth | 1/10 to 10 oct., shelving filters |
| (6 and 12 dB) |
Control range | +15 to |
Dynamic equalizer (DEQ) |
|
Type | max. 3 independent, fully |
| parametric filters per channel |
Frequency range | 20 Hz to 20 kHz |
Bandwidth | 1/10 to 10 oct., shelving filters |
| (6 and 12 dB) |
Control range | +15 to |
Threshold | variable from 0 to |
Attack | 0 to 200 msec |
Release | 20 to 4,000 msec |
Ratio | 1:2 to 1:100 |
Feedback Destroyer (FBD) |
|
Type | digital signal analysis for |
| feedback identification |
Filter | max. 10 digital notch filters per |
| channel, programmable or as |
| automatic feedback suppression |
| system |
Frequency range | 20 Hz to 20 kHz |
Bandwidth | 1/10 to 1/60 oct. |
Control range | 0 to |
20 | 7. SPECIFICATIONS |