4EUROLIGHT LD6230 Installation Instructions

The BEHRINGER EUROLIGHT LD6230 Dimmer Pack was developed to meet the highest demands of light engineering. Its wide-ranging functions make it an all-purpose workhorse for various commercial applications (TV studios, theatre or live events).

The EUROLIGHT LD6230 has all the important features needed to control your lighting equipment, yet its controls are clearly arranged and simple to use. You can select between digital DMX or analog control. You get trouble-free operation with the extensive LEDs used for signal error detection.

Important Information

Installation as well as initial operation must be performed by qualified personnel. Always assure that your LD6230 is completely disconnected from the mains before removing the casing cover.

The LD6230 was designed for indoor use only.

Please keep in mind that sudden temperature changes (e.g. bringing your equipment from colder environments into warmer environments) may cause condensation on electronic components, leading to possible equipment damage and physical harm to the operator.

Please adhere to all applicable national safety standards during installation.

Please read the installation instructions and the enclosed user’s manual in their entirety to familiarize yourself with the LD6230 and all of its functions. Please follow all instructions and store both the installation instructions and the manual in a safe place for future reference.

Please assure that your EUROLIGHT is sufficiently cooled and that it is not placed near heat sources that could cause overheating.

If you want to run your EUROLIGHT on mains voltage other than factory-specified voltage, contact the nearest BEHRINGER service center.

To effectively limit harmonic currents and avoid voltage fluctuations that could affect other electrical appliances, connect this equipment to an AC outlet that complies with all applicable technical standards. In all other cases, contact your local power supply provider for advice prior to usage.

Mains/Illuminant Connectors

To facilitate additional flexibility, your dimmer pack has a connector terminal strip. Cable bushings for connecting to the mains and your illuminants are located in the back. Flexibility is further enhanced with the option to retrofit a CEE connector and a 16-pin HARTING connector.

Both fixed and mobile installations require compliance with IEC 61010-1:2001 (EN 6110-1:2001). In particular, a 3-phase separator (pursuant IEC60947-1 and IEC60947-3) needs to be included in the installation. This separator needs to be labeled according to IEC 60417-50008 and IEC 0417-5007.

To assure compliance with Directive 89/336/EEC, only use specified upstream line filters with your EUROLIGHT. Using it without line filters specified by BEHRINGER may lead to electromagnetic interference. More detailed information on this subject can be found at behringer.com.

Safety and Initial Operation

As soon as you connect your LD6230 to the mains, internal controls are activated. The six automated fuses (circuit breakers) can all handle 10 A and serve as overload protection for the connected equipment.

Please keep in mind that activating circuit breakers 1, 2, 3, 4, 5 or 6 also means that the respective channels can conduct voltage.

Electronic controls are additionally protected with triple high-sensitivity fuses located on the main board.

Defective fuses must be replaced with fuses with identical rating!

The LD6230 is a Class I device in which a low-Ohm protective ground wire is an integral part of its safety design.

During the installation, make sure that a low-Ohm protective conductor (< 0,1 Ohm) exists between all bare metal parts and the grounding on the main connector.

 

 

 

 

 

Output Channels

 

 

Phase

 

CH 1*

 

CH 2

CH 3*

CH 4

CH 5*

CH 6

L1

 

X

 

X

 

 

 

 

 

 

 

 

 

 

L2

 

 

 

 

X

X

 

 

L3

 

 

 

 

 

 

X

X

* Activation of control electronics and respective output channel

Connector Terminal Strip

The connector terminal strip of your LD6230 is laid out for cables with diameters between 0.326 mm2 (AWG 22) and 4 mm2 (AWG 12). When using flexible access lines, cable end contacts corresponding to manufacturer specifications have to be used. To assure good contact, skin the cable endings between 9 - 13 mm.

During the installation, all applicable national standards need to be adhered to.

(2)

(2)

(4)

(3)

(1)

Illustration: LD6230 connector terminal strip

When your LD6230 leaves the assembly plant, all incoming and outgoing neutral conductor connectors (3) are bridged. The incoming phases L1/L1, L2/L2 and L3/L3 (1) are always connected to one another in pairs and switched to the overload protection of the channels 1 to 6. They protect output connectors E1 to E6 (4). Each of the channels can handle currents of maximum 10 Amperes. The green-yellow conductors (2) (PE) may only be used as protective conductors.

The lowest cable gauge between L1 and L3, incoming neutral conductor (N) and protective earth (PE) is 4 mm2 (AWG 12). For outgoing channels E1 to E6, use cables with gauges corresponding to the loads used (2.5 mm2 (AWG 14) or 1.5 mm2 (AWG 16)).

Output assessment [A] Nominal cross section [mm²] (EU)

AWG (USA)

6-10

 

16

1.5

13-16

2.5

14

18-25

4

12

During the installation, please adhere to all manufacturer instructions. Regardless from mains supply voltage, the maximum output current of the EUROLIGHT LD6230 is 10 A per dimmer circle.