5EUROLIGHT LD6230 Installation Instructions
◊Please make sure that each dimmer load is connected to a separate channel. Never connect more than one output to just one common neutral conductor.
◊ATTENTION: Due to electrocution danger, do not use your dimmer pack if there are bare cables visible.
Connection Options for Flexible Usage
Output Connector (HARTING)
In the back of your LD6230 there is a cable bushing for connecting your illuminants. Open the flap on the top of the LD6230 to get to the terminal clamps used for this purpose. Here you have the option to retrofit a
|
| PIN assignment/HARTING connector |
|
| ||||||
PIN 1 |
| Phase channel 1 |
| E1 |
| PIN 9 |
| Neutral channel 1 |
| N |
|
|
|
|
| ||||||
PIN 2 |
| Phase channel 2 |
| E2 |
| PIN 10 |
| Neutral channel 2 |
| N |
PIN 3 |
| Phase channel 3 |
| E3 |
| PIN 11 |
| Neutral channel 3 |
| N |
PIN 4 |
| Phase channel 4 |
| E4 |
| PIN 12 |
| Neutral channel 4 |
| N |
PIN 5 |
| Phase channel 5 |
| E5 |
| PIN 13 |
| Neutral channel 5 |
| N |
PIN 6 |
| Phase channel 6 |
| E6 |
| PIN 14 |
| Neutral channel 6 |
| N |
PIN 7 |
| free |
| – |
| PIN 15 |
| free |
| – |
PIN 8 |
| free |
| – |
| PIN 16 |
| free |
| – |
Ground wires need to be fastened to their respective PE connectors
CEE Power Supply Connector
Also located in the back is a cable bushing for the mains supply. Here, you can retrofit a
L3 L2
Specifications
Channels
| Number | 6 | |
| Load per channel | 0.2 A min./10 A max. | |
| Maximal load per channel | 10 A using a | |
| Frequency | 50/60 Hz | |
Inputs |
| ||
| Power supply | ||
|
|
| terminal block/PG cable screw joint, |
|
|
| CEE connector (optional installation by |
|
|
| qualified personnel) |
| Analog | 0 to +10 V via 8 pin DIN | |
| Digital | DMX512 via XLR 5 pin | |
Outputs |
| ||
| Digital | DMX512 via XLR 5 pin | |
| Load | Internal terminal block/PG cable screw | |
|
|
| joint, HARTING® (optional installation by |
|
|
| qualified personnel) |
System Fuses |
| ||
| Load securing per channel | 10 A cable protection switch (type C) | |
| Control section fuse | 2 x T 100 mA H/250 V 1 x T 160 mA | |
|
|
| H/250 V for voltage range 220 - 230 V |
|
|
| (EU) 2 x T 160 mA H/250 V 1 x T 315 mA |
|
|
| H/250 V for voltage range 120 V (UL) |
Power Supply |
|
N L1
CEE connector pin allocation
◊Removable mains connector cables with mains interconnections (pursuant IEC60320) must match the minimal
The interconnection and the cable must comply with prevalent nominal values (maximal voltage and current).
◊During the installation, please adhere to the instructions provided by the connector manufacturer.
Voltage
|
| USA/Canada | 120 V~, 60 Hz |
|
| Europe/U.K./Australia | 240 V~, 50 Hz |
| Maximum power consumption | 3 x 20 A | |
Dimensions/Weight |
| ||
| Dimensions (H x W x D) | approx. 3 1/3 x 19 x 15 9/10" | |
|
|
| approx. 84.3 x 482.6 x 403.8 mm |
| Weight | approx. 21.6 lbs / 9.80 kg |