5EUROLIGHT LD6230 Installation Instructions

Please make sure that each dimmer load is connected to a separate channel. Never connect more than one output to just one common neutral conductor.

ATTENTION: Due to electrocution danger, do not use your dimmer pack if there are bare cables visible.

Connection Options for Flexible Usage

Output Connector (HARTING)

In the back of your LD6230 there is a cable bushing for connecting your illuminants. Open the flap on the top of the LD6230 to get to the terminal clamps used for this purpose. Here you have the option to retrofit a 16-pin HARTING connector. To do that, you first have to remove the back-bearing cover sheet and connect the HARTING connector to the terminal clamps.

 

 

PIN assignment/HARTING connector

 

 

PIN 1

 

Phase channel 1

 

E1

 

PIN 9

 

Neutral channel 1

 

N

 

 

 

 

 

PIN 2

 

Phase channel 2

 

E2

 

PIN 10

 

Neutral channel 2

 

N

PIN 3

 

Phase channel 3

 

E3

 

PIN 11

 

Neutral channel 3

 

N

PIN 4

 

Phase channel 4

 

E4

 

PIN 12

 

Neutral channel 4

 

N

PIN 5

 

Phase channel 5

 

E5

 

PIN 13

 

Neutral channel 5

 

N

PIN 6

 

Phase channel 6

 

E6

 

PIN 14

 

Neutral channel 6

 

N

PIN 7

 

free

 

 

PIN 15

 

free

 

PIN 8

 

free

 

 

PIN 16

 

free

 

Ground wires need to be fastened to their respective PE connectors

CEE Power Supply Connector

Also located in the back is a cable bushing for the mains supply. Here, you can retrofit a 5-pin CEE 32 A mains connector by removing the back-bearing cover sheet and connect the CEE high-voltage connector to the connecting terminal. The following illustration shows how the connections are allocated:

L3 L2

Specifications

Channels

 

Number

6

 

Load per channel

0.2 A min./10 A max.

 

Maximal load per channel

10 A using a 3-phase connector

 

Frequency

50/60 Hz

Inputs

 

 

Power supply

3-phase connector, internal

 

 

 

terminal block/PG cable screw joint,

 

 

 

CEE connector (optional installation by

 

 

 

qualified personnel)

 

Analog

0 to +10 V via 8 pin DIN

 

Digital

DMX512 via XLR 5 pin

Outputs

 

 

Digital

DMX512 via XLR 5 pin

 

Load

Internal terminal block/PG cable screw

 

 

 

joint, HARTING® (optional installation by

 

 

 

qualified personnel)

System Fuses

 

 

Load securing per channel

10 A cable protection switch (type C)

 

Control section fuse

2 x T 100 mA H/250 V 1 x T 160 mA

 

 

 

H/250 V for voltage range 220 - 230 V

 

 

 

(EU) 2 x T 160 mA H/250 V 1 x T 315 mA

 

 

 

H/250 V for voltage range 120 V (UL)

Power Supply

 

N L1

CEE connector pin allocation

Removable mains connector cables with mains interconnections (pursuant IEC60320) must match the minimal load-carrying capacity of the connector or must comply with the IEC60799 standard.

The interconnection and the cable must comply with prevalent nominal values (maximal voltage and current).

During the installation, please adhere to the instructions provided by the connector manufacturer.

Voltage

 

 

USA/Canada

120 V~, 60 Hz

 

 

Europe/U.K./Australia

240 V~, 50 Hz

 

Maximum power consumption

3 x 20 A

Dimensions/Weight

 

 

Dimensions (H x W x D)

approx. 3 1/3 x 19 x 15 9/10"

 

 

 

approx. 84.3 x 482.6 x 403.8 mm

 

Weight

approx. 21.6 lbs / 9.80 kg

BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above values and/or illustrations.