EUROPOWER PMP1000/PMP3000/PMP5000

5 WIRING EXAMPLES

Fig. 5.1: Stereo operation

For stereo operation the POWER AMP switch must be set to its upper position (MAIN or MAIN L/MAIN R). Outputs A and B provide the stereo main signal for passive speakers. The preamp monitor output is connected to two parallel active speakers, which are used as on-stage monitors. Use the footswitch to enable/disable the effects processor.

Fig. 5.2: Bridged mono operation

This illustration shows the power mixer with a sub-woofer connected to OUTPUT B. For a bridged mono operation to

OUTPUT B, the AMP MODE selector switch must be set to its lower position “BRIDGE”. A separate stereo power amp (BEHRINGER EUROPOWER EP1500) connected to the preamp main outputs delivers the stereo main signal. Two active monitor speakers for on-stage operation are connected to the preamp monitor output.