16XENYX X1622USB/X1832USB/X2222USB/X2442USB User Manual
5.3 Inserts |
|
| 5.6 Voltage supply, phantom power supply | ||||||||||
|
|
|
| and fuse | |||||||||
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X1622USB
Fig. 5.3: Insert points
◊On the 2442FX the channel insert points are located
on the control panel between the line input and the GAIN control.
Insert points are very useful to process channel signals with dynamic processors or equalizers. Unlike reverb or other effects devices, whose signals are usually added to the dry signal, dynamic processors are most effective on the complete signal. In this case, aux send paths are a
They are
5.4 Direct outputs (X2442USB only)
X2442USB
Fig. 5.4: Direct outputs
DIRECT OUTPUTS
The direct outputs of the X2442USB (1 each per mono input channel) are ideal for recording if several tracks are to be recorded simultaneously. These unbalanced phone jacks are
5.5 USB input/output
Fig. 5.5: USB input/output
The XENYX mixer line has
Connect the USB type B plug into the USB jack on the mixer, and the other end into a free USB port on your computer. There are no required drivers, but we recommend that PC users install the included ASIO driver. The driver can also be downloaded from behringer.com.
All Models
Fig. 5.6: Voltage supply and fuse
FUSE HOLDER/IEC MAINS RECEPTACLE
The console is connected to the mains via the cable supplied, which meets the required safety standards. Blown fuses must only be replaced by fuses of the same type and rating. The mains connection is made via a cable with IEC mains connector. An appropriate mains cable is supplied with the equipment.
POWER switch
Use the POWER switch to turn on the mixing console. The POWER switch should always be in the “Off” position when you are about to connect your unit to the mains.
To disconnect the unit from the mains, pull out the main cord plug.
When installing the product, ensure that the plug is easily accessible. If mounting in a rack, ensure that the mains can be easily disconnected by a plug pull or by an
◊Attention: The POWER switch does not fully disconnect the unit from the mains. Unplug the power cord completely when the unit is not used for prolonged periods of time.
PHANTOM switch
The PHANTOM switch activates the phantom power (necessary to operate condenser microphones) on the XLR sockets of the mono channels.
The red +48 V LED illuminates when phantom power is on. As a rule, dynamic microphones can still be used with phantom power, provided that they are wired in a balanced configuration. In case of doubt, contact the microphone manufacturer!
◊Connect microphones before you switch on the phantom power supply. Please do not connect microphones to the mixer
(or the stagebox/wallbox) while the phantom power supply is switched on. In addition, the monitor/PA
◊Caution! Please also note the information given in chapter 6.2.1 “Audio connections”.
SERIAL NUMBER
Please note the important information on the serial number given in chapter 1.3.3.
behringer.com