R

F6H350-USB

F6H500-USB

F6H650-USB

INTRODUCTION

Thank you for purchasing a Belkin Uninterruptible Power Supply (UPS). Each year, several natural and man made occurrences put the power supplied to your electronics in your home or office in jeopardy. At risk are your hardware, software and data because of these power problems.

IMPORTANT SAFETY INSTRUCTIONS Please save this manual!

It contains important operating instructions and warranty information pertaining to your UPS.

Please save or recycle the packaging materials!

The UPS packaging was designed with great care to provide protection during shipment and delivery. These materials are invaluable if you ever have to return the UPS for service. Damage sustained during transit is not covered under the warranty.

Federal Communications Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. To assure continued compliance, use only shielded interface cables when connecting to computer or peripheral devices. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

CONTENTS

You should have received the following: 1 – UPS unit

1 – Sentry Bulldog Shutdown Software

1 – USB Cable

1 – Phone Line Cable

UPS FEATURES AND FUNCTIONS

Before installation, please inspect the UPS upon receipt. Make sure that nothing is damaged.

Your UPS features 3 LED indicators. Each is marked by a power icon; please familiarize yourself with this chart, as it will assist you in the use of your UPS.

Indicator

Condition

Description

 

- Solid green

AC power is on

ON-LINE

 

 

 

 

This condition for the

 

 

On-Battery and

 

 

Low-Battery LED can

 

 

indicate 1 of 3 problems:

 

 

1. The UPS is on battery

 

 

backup and an

 

 

intermittent audible

 

- Flashing Red

alarm is on. The UPS

ON-BATTERY

will begin shutdown

 

 

procedure.

and

LED with Audible

 

LOW-BATTERY

 

2. Battery is low. The UPS

 

Alarm (Beeping)

 

will start shutdown. The

 

 

buzzer sounds an

 

 

audible alarm.

 

 

3. There is a problem with

 

 

the UPS. The LED will

 

 

be lit continuously and

 

 

the buzzer will sound

 

 

audible alarm for 10

 

 

sec.

 

 

The Site Wiring fault LED

 

 

can indicate 1 of 2 possible

 

 

conditions:

 

 

1. Open or high resistance

 

 

on the ground line

SITE WIRING

 

2. Hot or neutral polarity

 

circuit

FAULT

 

- Solid Red

*Note in order for your UPS

 

 

 

to work properly, you must

 

 

have a properly grounded

 

 

AC circuit. If your Site

 

 

Wiring Fault LED is lit,

 

 

please contact an

 

 

electrician to properly wire

 

 

this circuit.

 

Chart 1

 

ALARMS

Back Up (Slow Alarm)

When in “BACK UP” on battery mode, the RED LED illuminates and the UPS sounds an audible alarm. The alarm stops when the UPS returns to LINE NORMAL operation.

Low Battery (Rapid Alarm)

In “BACK UP” mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shuts from a depleted battery or returns to LINE NORMAL operation.

Fault (10 Seconds Continuously)

When the output is shorted, the UPS emits a 10 seconds continuously alarm to warn of a short condition. Disconnect the equipment prior to checking the equipment.

FRONT PANEL

2

3

1

Diagram 1

1.UPS Outlets (See #1 on Diagram 1)

These outlets are your battery back up outlets. We strongly recommend that only sensitive equipment such as your computer and monitor should be plugged into these outlets. Caution: Never connect a laser printer or scanner to the backup outlets of UPS with other computer equipment. A laser printer or scanner draws significantly more power when in use than when sitting idle. This may overload the UPS.

Should a power outage occur, your battery backup would automatically turn on. Power (utility or battery) is not supplied to these outlets when the UPS is switched off.

Do not plug any surge protectors or power strips into the battery back-up outlets (i.e. daisy chaining).

2.SURGE Protected outlets (See #2 on Diagram 1)

These outlets do not provide power during a power outage.

Equipment such as computer peripherals, printers, fax machine’s, or a desk lamp may be plugged into these outlets. The On/Off button does not control these outlets.

3. The On/Off button has 3 functions:

1. Turns on the UPS. Depress button at least 2 seconds. The green light will come on.

2.

Cold Start function. Assuming the battery is

 

 

charged the UPS will work without it being

 

 

plugged into an outlet. Depress and hold the key

 

 

for at least 2 seconds to turn on the UPS. The

 

3.

Silence function. During “On Battery Mode”, the

Battery Light

 

 

audible sound can be turned “ON” or “OFF” by

 

 

depressing the switch.

 

Side Panel A

1

 

Circuit Breaker

AC Input

 

 

3

Push to Reset

OUT

 

Phone/Fax

 

Modem OUT

Protection

Refer to Bottom for

IN

2

 

Cautionary Markings

 

 

Diagram 2

4.AC Input Power Cord (See #1 on Diagram 2) Provides power to your UPS.

5.Phone/ Fax/ Modem Surge Protection (See #2 on Diagram 2)

The Phone/ Fax/Modem lines are surge protected. There is one input jack and two output jacks. This allows you to split one telephone connection to two separate devices.

6.AC Breaker (Circuit Breaker; See #3 on Diagram 2)

Should a power overload occur, the circuit breaker would trigger the UPS to turn off AC power. In order to restore the power, depress the circuit breaker button to reset, then depress the Power button.

Side Panel B

USB Communication Port

Diagram 3

7.Your UPS features a USB communication port. Installation of the cable and software is optional. This allows the UPS to connect to you computer. The Sentry Bulldog Software will not work if the UPS is not connected to you computer. This does not mean the battery backup feature will not work without the software and cable installed. The UPS will still provide backup power but you will be unable to utilize the data management capabilities of the software.

INSTALLATION

Note!

Before installation, please inspect the UPS Upon receipt. Make sure that everything inside the package is not damaged.

Connect to AC Utility Power

Connect the AC inlet to utility power via the power cord. Please make sure there are no devices plugged into the UPS unit. Check to see if the “Site Wiring Fault” indicator is lit or not. If it is lit, please have the utility wiring inspected by an electrician.

Charging the Battery For best results, charge the battery for 6 hours prior to initial use. The UPS charges its battery whenever

it is connected to the utility power. Should you see Battery Light the red battery light come on, the battery may need

immediate charging.

Turning on the UPS

Turn on your UPS by depressing the On/Off button for approximately 2 seconds. You will see the green indicator light come on.

Plug in Power Devices

Plug your devices into the AC outlets on the top of the UPS. To use

the UPS as a master on/off switch, make sure all of the loads are

switched on.

 

Caution: Never connect a laser printer or

 

scanner to the backup outlets of UPS with

 

other computer equipment. A laser printer or

 

scanner draws significantly more power

 

when in use than when idles. This may

 

overload the UPS.

LaserPrinter

 

Connect the phone/ fax/ modem lines

Connect a single phone / fax/ modem line into the surge protected sockets on the right of the UPS. The RJ-11 modular sockets accept standard single line telephone connections.

Plug one end of the phone cable you received into your telephone wall jack and plug the other end into the jack marked IN. You may now plug a phone, fax or modem into the two jacks marked OUT. (See Diagram 4)

Phone

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modem

 

 

 

 

To Telephone Socket

/ Fax

Diagram 4

Note: This connection is optional but highly suggested as phone / fax / modem lines often carry dangerous surges and spikes. The UPS works properly without a phone / fax/ modem connection.

Caution: The phone/fax/modem protection feature could be rendered inoperable if improperly installed. Make sure that the telephone line from the wall is plugged into the connector marked “IN”, and the devices to be protected (phone/ fax/ modem) are plugged into the connector marked “ OUT”.

USB (Universal Serial Bus) Communication Port

A USB port is provided to relay the signal to support DOS, WINDOWS, and the other operating system.

Communication port

(Optional) To fully utilize the Sentry Bulldog Shutdown Software; you will need to connect the UPS to your computer. Connect the USB cable to your UPS then connect the other end to the USB port on your computer.

Software Installation (Optional) Compatible with any computer running the following: 95/98/ME/NT4/2000/XP & Novell 3.X & Higher

1.Your UPS features the Sentry Bulldog Shutdown Software. This allows you to protect and save your data should a power outage occur, as well as safely shutdown your computer in your absence. This software is compatible with Windows 95/98/ME/NT4/2000/XP and Novell 3.X & higher.

2.To install the software, please place the CD into the CD drive of your computer.

3.Your computer should automatically run (AutoPlay) the CD. If this does not occur, go to the Run feature on your Start icon (lower left corner) on your screen. Please enter the CD drive, it may be D: Should you continue to have a problem, please refer to your computer’s owner’s manual for the correct drive. Upon entering the drive Run setup.exe. to execute the software.

4.Once uploaded, please click the Bulldog icon on the screen.

5.Click Install Belkin Sentry Bulldog for Win 95/98/ME/NT4/2000/XP

6.InstallShield Wizard will appear onscreen, click Next.

7.Please read the License Agreement and click Yes.