Models C36600X (Z36 6 00 X) [C3Y0..U4X(2 or 5)A]
Adapting to different types of gas
Burner | Position | Injector | Gas | Pressure | Max Rate | Min Rate | |||
|
| diam. [mm.] | Type | [i.w.c.] | [BTU/h] | [W] | [BTU/h] | [W] | diam. [mm] |
Auxiliary | Front R | 0,90 | NG | 4” | 3400 | 996 | 900 | 264 | Regulated |
|
| 0,54 | LP (Propane) | 11” | 3400 | 996 | 900 | 264 | 0,29 |
Rear L & C | 1,18 | NG | 4” | 6100 | 1787 | 1500 | 439 | Regulated | |
| Front C | 0,70 | LP (Propane) | 11” | 6100 | 1787 | 1500 | 439 | 0,36 |
Rapid | Rear L | 1,55 | NG | 4” | 10400 | 3047 | 2500 | 732 | Regulated |
|
| 0,92 | LP (Propane) | 11” | 10400 | 3047 | 2500 | 732 | 0,47 |
Dual Burner | Front L Inner | 0,80 | NG | 4” | 2800 | 820 | 900 | 264 | Regulated |
| 0,49 | LP (Propane) | 11” | 2800 | 820 | 900 | 264 | 0,29 | |
| Front L Outer | N°2 x 1,15 | NG | 4” | 12000 | 3516 | 4500 | 1318 | Regulated |
|
| N°2 x 0,70 | LP (Propane) | 11” | 12000 | 3516 | 4500 | 1318 | 0,65 |
Models C36500X (Z36 5 00 X) | [C3W0..U4X(2 or 5)A] |
|
| |||||||
Adapting to different types of gas |
|
|
|
|
|
|
| |||
Burner | Position | Injector | Gas | Pressure | Max Rate | Min Rate | ||||
|
| diam. [mm.] | Type | [i.w.c.] | [BTU/h] | [W] | [BTU/h] |
| [W] | Diam. [mm] |
Auxiliary | Front R | 0,90 | NG | 4” | 3400 | 996 | 900 |
| 264 | Regulated |
|
| 0,54 | LP (Propane) | 11” | 3400 | 996 | 900 |
| 264 | 0,29 |
Rear L and R | 1,18 | NG | 4” | 6100 | 1787 | 1500 |
| 439 | Regulated | |
|
| 0,70 | LP (Propane) | 11” | 6100 | 1787 | 1500 |
| 439 | 0,36 |
Rapid | Rear L | 1,55 | NG | 4” | 10400 | 3047 | 2500 |
| 732 | Regulated |
|
| 0,92 | LP (Propane) | 11” | 10400 | 3047 | 2500 |
| 732 | 0,47 |
Dual Burner | Centre Inner | 0,80 | NG | 4” | 2800 | 820 | 900 |
| 264 | Regulated |
| 0,49 | LP (Propane) | 11” | 2800 | 820 | 900 |
| 264 | 0,29 | |
| Centre Outer | N°2 x 1,15 | NG | 4” | 12000 | 3516 | 4500 |
| 1318 | Regulated |
|
| N°2 x 0,70 | LP (Propane) | 11” | 12000 | 3516 | 4500 |
| 1318 | 0,65 |
CAUTION: save the orifices removed from the appliance for future use
Regulation of burners
Work surface burner adjustment: follow the instructions below to adjust the work surface burner minimum:
1)Light the burner and set the knob to the MINIMUM position (small flame).
2)Remove the knob of the valve that is press fit on the rod of that valve.
3)The cooker is equipped with safety valves, use a small slotted screwdriver the choke valve located on the valve body and turn the choke screw to the right or left until the burner flame is adjusted to minimum
4)Make sure that the flame does not go out when switching quickly from the MAXIMUM to the MINIMUM position.
WARNING: The
9