Best ILB9 Wiring Plate Position, Ducting Options, Mounting Options, Blower Discharge Positions

Models: ILB9 ILB11

1 4
Download 4 pages 55.38 Kb
Page 3
Image 3
WIRING

 

 

MODELS ILB9 ! ILB11

WIRING

 

Page 3

 

WIRING PLATE POSITION

BLACK

 

TO

 

 

BLACK

EDGE

 

 

OF HOUSING

 

 

GROUND TO

VERTICAL

 

WIRING PLATE

 

POWER

 

 

 

 

CABLE

 

WIRING

CONNECTION

 

PLATE

 

 

 

HORIZONTAL POWER

WHITE

 

CABLE CONNECTION

 

 

TO

 

Wiring plate mounts to side or top of housing.

WHITE

 

 

120 VAC LINE IN

DUCTING OPTIONS

(from range hood)

 

 

Ventilator can be wired from outside of housing.

 

BLOWER DISCHARGE POSITIONS

Use UL approved connectors to wire per local codes.

MOUNTING OPTIONS

¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position.

 

 

Factory-Shipped

 

Factory-Shipped

11/ 8"

Straight-Through

1½"

Straight-Through

MAX.

Discharge

to

 

 

2½"

Discharge

 

 

 

 

 

22"

 

18"

 

 

 

 

MOVABLE

DUCT

Housing

DUCT

PANEL

CONNECTOR

rotated &

CONNECTOR

 

(outlet)

movable panel

(outlet)

 

 

covers previous

 

 

open side.

 

 

 

 

MOVABLE

 

 

 

PANEL

DUCT

 

DUCT

(Change to this

 

location)

CONNECTOR

 

CONNECTOR

(intake)

 

(intake)

 

Mounting brackets in

Mounting brackets flipped

factory-shipped position -

over and mounted to

mounted directly to joists.

additional framing.

(Outlet parallel to joists.)

(Outlet perpendicular to joists.)

(New construction)

(New or Existing construction)

Housing

 

 

Converted to

 

 

Right-Angle

1½"

Factory-Shipped

Discharge

to

Straight-Through

 

2½"

Discharge

 

 

18"

 

22"

 

 

Mounting brackets flipped

Mounting brackets flipped

over and mounted to

over and mounted to top of

additional framing.

housing. Housing secured

(Outlet vertical.)

with cables.

(New or Existing construction)

(Outlet parallel to joists.)

 

(New or Existing construction)

Ventilator shown in

Ventilator shown in right-

straight-through discharge

angle discharge position.

position. (Factory shipped)

(Change movable panel to

 

new location as shown.)

DUCTING (Vertical blower discharge)

 

ROOF CAP

8” X 12” TO

10” ROUND

10” ROUND TRANSITIONS

DUCT

10” ROUND

 

DUCT

 

Typical ductwork connection to a ventilator converted to right-angle discharge.

Page 3
Image 3
Best Wiring Plate Position, Ducting Options, Mounting Options, Blower Discharge Positions, Page, MODELS ILB9 ! ILB11