AIR CLEANER SAFETY

PLEASE READ THESE

IMPORTANT SAFETY

INSTRUCTIONS

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. These precautions include:

• Read all instructions before using the appliance.

• To avoid fire or shock hazard, plug the appliance directly

into a 120V AC electrical outlet.

• If the filter is covered by a bag when shipped: Remove

plastic bag before use.

• Keep the cord out of heavy traffic areas. To avoid fire

hazard, NEVER put the cord under rugs, near heat

registers, radiators, stoves, or heaters.

• To protect against electrical hazards, DO NOT immerse

the appliance in water or other liquids. Do not use near

water.

• Close supervision is necessary when any appliance is

used by or near children, or disabled persons.

• Always unplug the air cleaner before moving or cleaning

the unit, opening the grill, changing the filters and

whenever the unit is not in use. To disconnect the unit,

be sure to pull the plug and not the cord.

• NEVER drop or insert any objects into the openings of

the unit.

• DO NOT operate any appliance with a damaged cord

or plug. If the motor fan fails to operate or the unit has

been dropped or damaged in any manner, return

appliance to manufacturer for examination and/or repair.

• Use appliance only for intended household use as

described in this manual. Any other use not recommended by

the manufacturer may cause fire, electric shock, or injury

to persons. The use of attachments not recommended or

sold by Jarden Consumer Solutions may cause hazards.

• DO NOT use outdoors.

• NEVER place on a soft surface such as a bed or sofa

as this could cause the unit to tip over and block the air

inlet or outlet grills.

• Keep unit away from heated surfaces and open flames.

WARNING: To reduce the risk of fire or electric shock, DO NOT use this air cleaner with any solid-state speed control device.

DO NOT place anything on top of unit.

NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the air cleaner.

Always turn the appliance off before unplugging it.

The ionizer may cause a static charge to build up on the air outlet grill. A static charge may be felt if the unit is not properly grounded. To avoid a static charge, plug the unit's three-prong plug into a grounded outlet, or properly install a ground adaptor (see PLUG SAFETY). The static charge will not occur if the ionizer is off.

The ionizer in this appliance produces less ozone than the UL established limits of 50ppb. However, in high concentrations, ozone can be harmful to birds and small pets. To prevent ozone buildup, we suggest using the ionizer in well ventilated areas with the fan on.

This appliance should only be used in a room with temperatures between 40° F and 110° F.

PLEASE SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

PLUG SAFETY

To reduce the risk of electric shock,

THIS PRODUCT IS EQUIPPED WITH A 3-

PRONG PLUG, a grounding type plug that has a third (grounding) pin.

The cord has a plug (A) as shown. An adapter (C) can be purchased for connecting three-blade grounding-type plugs to two-slot receptacles (B).

The green grounding wire or lug extending from the adapter must be connected to a permanent ground such as a

CORD SAFETY

The length of cord used on this appliance was selected to reduce tangling or tripping hazards.

If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the electrical rating of the air cleaner (see rating label marked on product).

Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.

FEATURES

GET TO KNOW YOUR AIR CLEANER

Your Bionaire® air cleaner features a Permanent HEPA-Type filter that removes up to 99% of airborne dust and pollen as small as 2 microns and helps reduce smoke, mold spores and pet dander from the air passing through the filter.

Permanent filters can be vacuumed every few months for easy cleaning.

Washable pre-filter captures larger particles and extends the permanent filter’s cleaning cycle.

Optional ionizer naturally improves performance and helps freshen the air.

Slim tower design allows placement in almost any area of the room.

IONIZER

This appliance has an optional ionizer feature which, when turned on, releases negative ions into outgoing filtered air to help the air purification process.

What Are Ions?

Ions are tiny particles that carry a positive or negative charge. They exist naturally around us: in the air, water, and ground. Both positive and negative ions are colorless, odorless, and completely harmless.

How Does The Ionizer Work?

Negative ions help air purification by attaching themselves to very small airborne particles in the room. These particles take on a negative charge and may join

with positively charged particles such as dust, pollen,

IMPORTANT NOTES:

Your ionizer may produce an occasional popping or cracking sound. This is normal and occurs when a small buildup of ions is discharged. After extended use, you may notice dust around the grills or front panel.

This is caused by negative ions exiting the air outlet, evidence of the ionizer’s air cleaning effectiveness.

You can remove the dust with a soft brush or clean, damp cloth.

Larger particles may be attracted to positively charged surfaces throughout the home, like walls or floors.

This may occur more frequently when the filter is nearing the end of its useful product life and unable to capture as many charged particles.

Excessive amounts of pet dander, dust, or smoke may decrease the life expectancy of the filter(s) and interfere with the ionization process.

To help prevent particles from attracting to surfaces throughout your home:

You may want to run the ionizer less often.

Check the condition of the filter(s) more frequently.

CAUTION: The ionizer in this appliance produces less ozone than the UL* established limits of 50ppb. However,

in high concentrations, ozone can be harmful to birds and small pets. To prevent ozone buildup, we suggest using the ionizer in well ventilated areas with the fan on.

IMPORTANT: Always clean the PERMAtech® filter at the recommended intervals (See CLEANING THE PERMAtech® FILTER). Using the ionizer with dirty filters may result in dirty particles exiting the air purifier and attracting to walls, carpets, furniture, or other household objects. These dirty particles may prove difficult to remove.

HEPA-TYPE PERMAtech® FILTER

The PERMAtech® filter allows easy maintenance and eliminates the hassle of filter replacement. HEPA-type (High Efficiency Particulate Air) filters are designed to remove up to 99% of airborne pollutants, at 2 microns or larger, from the air that passes through them. These include tobacco smoke, household dust, pet dander and pollen.

FILTER INDICATOR

The filter indicator light eliminates guesswork by letting you know when it is time to clean the filters.

D

F

E

J

Figure 1

C

B

A

H

G

I

BEFORE USE

1.Carefully unpack your air cleaner.

2.Select a firm, level surface with no obstructions to the air inlets or outlets.

3.If the filter is covered by a bag when shipped, remove plastic bag before use and place filters into unit.

OPERATING INSTRUCTIONS

IMPORTANT:

Remove all plastic bags from filters before use.

DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL.

TO OPERATE YOUR AIR CLEANER:

1.Plug into a 120V AC electrical outlet.

2.Press the power button ( PLEASE SAVE THESE IMPORTANT SAFETY INSTRUCTIONS ). The air cleaner will turn onto high and the power light will illuminate letting you know the power is on.

3.You can then select the desired speed setting. This air cleaner has three speed settings. You can select from HIGH ( FEATURES ), MEDIUM ( BEFORE USE ), or LOW ( CLEANING AND MAINTENANCE ) by pushing the desired operating speed control button on the control panel.

4.To release negative ions into the filtered air, press the ionizer button ( Manual background ) to ON and the light will illuminate.

CLEANING AND MAINTENANCE

CLEANING THE PERMATECH® FILTER

The PERMAtech® filter is designed to never need replacement. However, we recommend regular cleaning for optimal performance.

Every few weeks, check the condition of the filter.

After approximately 3 months of operation, a Filter Clean Indicator will alert you to clean the filter before further use.

TO CLEAN THE FILTER:

1.

Turn off and unplug the air cleaner.

2.

Remove the air inlet grill.

3.

Remove and examine the foam pre-filter.

 

• If it has collected dust or lint, remove and wash it in

• DO NOT attempt to repair or adjust any electrical or

mechanical functions on this unit. Doing so will void

your warranty. The inside of the unit contains no user

serviceable parts. All servicing should be performed by

Jarden Consumer Solutions or an authorized Jarden

Consumer Solutions service center.

properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available.

This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet, contact qualified electrician to install the proper outlet.

This product is for use on 120 volts. DO NOT ALTER THE PLUG IN ANY WAY.

smoke, and pet dander to form larger particles. The larger particles are then more easily captured by the filter system.

HIGH, MEDIUM, AND LOW SPEED SETTINGS

For optimum air filtration, operate your Bionaire® Air Cleaner continuously on the HI setting. Its rugged motor has been designed to give many years of use. For quieter operation (such as in a bedroom), select LOW setting.

*tested and listed by the Underwriters Laboratories, Inc.

A.POWER INDICATOR

B.SPEED CONTROL

C.POWER BUTTON

D.IONIZER CONTROL

E.FILTER SERVICE LIGHT

F.IONIZER LIGHT

G.INLET GRILL

H.WASHABLE FOAM PRE-FILTER

I.PERMAtech® FILTER

J.FILTERED AIR OUTLET

 

warm soapy water. Rinse and drip dry thoroughly

 

before placing it back into the grill inlet.

4.

Check the condition of the PERMAtech® filters and

 

remove if dirty.

5.

Clean the PERMAtech® filter.

Page 2