Bionaire BU2200 warranty Important Instructions, Setup Instructions, Operating Instructions

Models: BU2200

1 2
Download 2 pages 40.22 Kb
Page 2
Image 2

BU220007EM1.qxd 6/11/07 2:35 PM Page 2

HUMIDIFIER SAFETY

PLEASE READ AND SAVE THESE IMPORTANT SAFEGUARDS

IMPORTANT INSTRUCTIONS

When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

1.Read all instructions before using the appliance.

2.To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.

3.Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers.

4.DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. Locate your humidifier on an inside wall near an electrical outlet. The humidifier should be at least 4’’ away from the wall for best results.

5.NEVER place humidifier in an area where it is accessible to children. NEVER use humidifier in a closed room, particularly where a child may be sleeping, resting, or playing (a closed room may result in excessive humidity).

6.WARNING: Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet. Failure to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord.

7.Never place anything over moisture outlet when the unit is running.

8.NEVER drop or insert any object into any openings.

9.DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair.

10.Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold by the manufacturer may cause hazards.

11.DO NOT use outdoors.

12.Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under

the humidifier. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.

13.DO NOT allow the Moisture Outlet to directly face the

wall. Moisture could cause damage, particularly to wall paper.

14.Humidifier should be unplugged when not in use.

15.NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit.

16.This humidifier requires daily and weekly maintenance

to operate appropriately. Refer to daily and weekly cleaning procedures. Use only cleaners and additives recommended by the manufacturer.

17.NEVER use detergents, gasoline, glass cleaner, furniture polish, paint thinner, or other household solvents to clean any part of the humidifier.

18.Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF.

19.Do not use humidifier in an area where humidity level is in excess of 50%. Use a hygrometer, available at your local retailer or through the manufacturer, to measure the humidity.

20.DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.

21.Never place housing under water flow or immerse in liquids.

22.Do not plug in the cord with wet hands: electric shock could result.

23.Do not pour water in any openings other than the water tank.

24.To prevent damage to surfaces, do not place humidifier under overhanging surfaces.

25.NEVER operate unit without water in the tank.

26.Do not move unit while it is operating.

27.Use both hands when carrying full tank of water.

PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

CONSUMER SAFETY INFORMATION

NOTE: This is an electrical appliance and requires attention when in use.

NOTE: If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage.

NOTE: DO NOT block air inlet or outlet.

CORD AND PLUG INSTALLATION SAFETY INSTRUCTIONS

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the

plug. If it still does not fit, contact a qualified electrician to install the proper outlet.

DO NOT DEFEAT THE SAFETY PURPOSE OF THIS POLARIZED PLUG IN ANY WAY

The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier. Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.

SETUP INSTRUCTIONS

1.Select a location for your humidifier, on a flat, level surface about 4 Inch away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which can be damaged by too much moisture or water. Place on a moisture-resistant surface.

2.Remove the tank from the main housing.

3.Bring the tank to the sink, turn upside down and twist off the tank cap by turning counter clockwise. Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank

FIRMLY.

4.Carefully bring the filled tank over to the humidifier,

holding it level to avoid sloshing or spilling of water.

5.Carefully place tank back onto the base to prevent water from spilling. The tank will immediately begin to empty into the base.

6.Plug the humidifier into a 120V electrical outlet.

OPERATING INSTRUCTIONS

1.To turn the unit on, press the Bionaire logo power button in front of the unit so that it illuminates.

2.When the humidifier runs out of water, the transducer will automatically shut off and the fan will keep running to dry any residual water out of the base and chamber.

3.Once the tank is empty, press the power button to turn the unit off and unplug the unit.

4.Before refilling the tank, empty or sponge up any residual water from the base and tank. Follow daily maintenance instructions.

5.Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank FIRMLY.

6.Carefully place the tank onto the base. The tank will immediately begin to empty into the base.

7.Plug the humidifier into a 120V electrical outlet.

WARNING: DO NOT move the humidifier while it is operating with water in the tank or in the humidifier base. The moving action of the water may activate the water tank’s release nozzle and overfill the transducer cavity. This may cause the humidifier to function intermittently, or stop emitting mist. Should this occur, turn off and unplug the unit, then remove the excess water from the humidifier base.

IMPORTANT: If you do not plan to use your humidifier for two or more days, make sure any residual water is drained

Fig. 1

Exhaust grill

 

Removable shatter-proof water tank

Backlight mist chamber

Transducer housing

Base of unit

Power button

Fig. 2

Removable shatter-proof tank

Transducer access door

Main housing unit

Fig. 3

Removal of transducer access door

from the water tank and base to prevent any algae or bacteria growth in stagnant water. Make sure the tank is dry.

How Does The RevolutionTM Ultrasonic Humidifier Work?

1.Water from the tank is dispersed into the base reservoir where a transducer vibrates the water at ultrasonic speed (1.7 million times per second).

2.The transducer breaks the water into mist and sends it into the RevolutionTM humidifier's front chamber. A vortex air flow propels the smaller finer mist particles up and disperses the fine vapor into the air through the top of the grill, while the denser larger water molecules fall back into the base.

3.The resulting mist emitted from the RevolutionTM is much finer and lighter than from typical ultrasonic humidifiers. The benefit is faster evaporation and faster humidity room coverage.

NOTE: Do not let water sit in tank for extended periods. This can encourage bacterial growth.

CLEANING AND MAINTENANCE INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry,

heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use.

In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the humidifier's tank and become airborne. You must routinely follow the cleaning and maintenance procedures in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up.

DAILY MAINTENANCE

1.Be sure the unit is OFF by pressing the power button so that it no longer illuminates. Unplug the unit from the electrical outlet.

2.Remove the tank from the humidifier and carefully bring to a sink or tub. Hold the base of unit level as you carry it to prevent excess water from sloshing or spilling.

Place in sink or tub.

3.Drain or sponge up any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean and dry with a clean cloth or paper towel.

4.Refill with cool tap water. Do not overfill.

WEEKLY MAINTENANCE

To Remove Scale

1.Repeat steps 1-3 above.

2.Refer to Fig. 2 and Fig. 3 for access to transducer.

3.Clean all surfaces with a soft brush. Gently scrub the area around the transducer with a soft brush. Remove the scale by wiping the entire base with a cloth dampened with undiluted white vinegar.

4.Rinse clean with warm water to remove cleaning solution before disinfecting the tank.

To Disinfect Tank

1.Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach.

2.Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.

3.Carefully empty the tank after 20 minutes, and rinse with warm water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel.

Page 2
Image 2
Bionaire BU2200 Important Instructions, Setup Instructions, Operating Instructions, Cleaning and Maintenance Instructions

BU2200 specifications

The Bionaire BU2200 is a premium air purifier designed to enhance indoor air quality by effectively filtering out common pollutants such as dust, allergens, and odors. This device is particularly suitable for households with pets, allergy sufferers, and individuals seeking to maintain a healthier living environment.

One of the main features of the Bionaire BU2200 is its advanced filtration system, which includes a true HEPA filter. This high-efficiency particulate air (HEPA) filter is capable of capturing up to 99.97% of microscopic particles as small as 0.3 microns, including allergens, pollen, smoke, and pet dander. The incorporation of a pre-filter also helps to extend the lifespan of the HEPA filter by trapping larger particles before they reach the HEPA stage.

In addition to its HEPA technology, the Bionaire BU2200 is equipped with an activated carbon filter. This component is designed to absorb and neutralize unpleasant odors from cooking, pets, and other sources, thereby improving the overall freshness of indoor air. The combination of these filters makes the BU2200 particularly effective at creating a cleaner, more pleasant living space.

Another noteworthy characteristic of the Bionaire BU2200 is its user-friendly design. The unit features a modern aesthetic that seamlessly fits into various home décor styles. It is compact and lightweight, allowing for easy placement in different rooms, whether it be the living room, bedroom, or office. The air purifier also includes intuitive control settings, often equipped with multiple fan speeds and a timer function, empowering users to customize their air purification experience according to their preferences.

The Bionaire BU2200 is designed for quiet operation, making it an ideal choice for night-time use or in home offices. This low-noise technology ensures that users can enjoy clean air without disruptive sounds.

Energy efficiency is another important aspect of the Bionaire BU2200. The device operates with minimal energy consumption, making it an environmentally friendly option for consumers who are conscious of their energy use while still maintaining optimal air quality.

In summary, the Bionaire BU2200 stands out in the air purifier market with its combination of advanced HEPA and activated carbon filtration technologies, user-friendly features, quiet operation, and energy efficiency. This model is a solid choice for anyone looking to improve their home’s air quality and foster a healthier living environment.