SRP-270

4. Self-Test

Run the self-test when first setting the printer or when encountering a problem. The following printer attributes can be assessed.

- Control Circuits, Mechanisms, Print Quality, and ROM Version

If no issue is found with the printer after running the self-test, examine the other devices or peripherals and software. This function is independent of such other devices and software.

Self-Test instructions are as follows.

1)Check to see that the paper is properly installed.

2)Turn off the printer power and close the printer paper cover.

3)Press the paper feed button and simultaneously turn on the printer power to commence the self-test.

4)The test ceases after printing the current printer status and the following message. (The 'PAPER LED' lamp blinks.)

SELF-TEST PRINTING.

PLEASE PRESS THE FEED BUTTON.

5)To additionally print the embedded characters in the printer, press the paper feed button once more.

6)The self-test ends automatically after the following message is printed.

**CHARACTER TEST COMPLETED **

Rev. 1.05