5
• Unlatch the fan cover from the bottom of the
vacuum
housing by pressing the
release tab (located near the front of the
vacuum
housing) and pulling the
cover open like a lid (figure B1).
NOTE: This interlock will disconnect the
electric circuit automatically and the unit will
not operate.
Attach the vacuum tube assembly to the
fan inlet on the
vacuum
housing (figure
C), insert the vacuum tube support tab
into the assembly slot (figure C1) on the
blower housing.
Push the lock button to lock the vacuum tube in place.
NOTE: This interlock will connect the electric circuit automatically and the unit
will operate.
COLLECTION BAG ASSEMBLY (FIGURE D)
NOTE:
Ensure the vacuum is switched off and
disconnected from the power supply before
attaching or removing the collection bag.
• Remove blower tube if attached.
• Push the collection bag on to the blower
housing until the lock lever engages the lock
hole as shown in figure D.
OPERATION
ALWAYS WEAR SAFETY GLASSES. WEAR A FILTER MASK IF
THE OPERATION IS DUSTY. USE OF RUBBER GLOVES AND
SUBSTANTIAL FOOTWEAR IS RECOMMENDED WHEN WORKING
OUTDOORS. FOR HOUSEHOLD USE ONLY.
WARNING: CUT HAZARD. When turning the tool off for tube
installation or any other reason, wait 10 seconds for the fan to stop
rotating before disassembly.
• Do not use in vacuum mode without the vacuum tubes and
collection bag in place.
Always switch off and remove the plug from the electrical supply when:
• Changing from blower to vacuum.
BLOWER MODE ASSEMBLY
NOTE: Ensure the blower is switched off and disconnected from
the power supply before attaching or removing the blower tubes.
The tube assembly must be assembled to the housing before use.
TUBE ASSEMBLY (FIGURE A)
To attach the two piece blower tubes to the blower, line up the tube
with the blower housing as shown in figure A. Push the tube into the
blower housing until the lock lever engages the lock hole in the tube.
• To rem
ove the tube depress the lock button and slide the tube off
the housing neck.
VACUUM MODE ASSEMBLY
VACUUM TUBE ASSEMBLY (FIGURES B, C, D)
NOTE:
Ensure the
vacuum
is switched off and disconnected from
the power supply before attaching
or removing the vacuum tube. The
vacuum tube and collection bag must be
assembled to the housing before use.
The vacuum tubes must be assembled
together before use.
• Align the notches and the tabs on the two
tube pieces. (figure B)
• Push the lower tube firmly into the upper
tube, until the tabs click into place. (Never
operate apart).
A

D

C

C1
B
B1