T e c h S P e c s

Cable Required —

Between hubs and remote units:

Category 5 solid unshielded or shielded twisted pair (UTP or STP), wired to the TIA/EIA-568A or (preferred) -568B standard, terminated with RJ-45 M connectors

Clamping Voltage — Up to 15 volts

Compatibility —

Video: VGA, SVGA, XGA, XGA-2, or RGsB (sync on green), although if your system has monitor ID-bit requirements, you might need to call Black Box for technical support;

Keyboard: IBM PC/AT or PS/2 compatible (PC/AT types require connector adapter);

Mouse: IBM PS/2 compatible two-button, Microsoft® IntelliMouse®, or Logitech® PS/2 compatible three-button

Compliance — CE Class B; FCC Part 15 Subpart B Class A, IC Class/classe A Distance (Maximum) —

ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA, ACU1006DSRA, ACU1006VRA, ACU1006DVRA:

16.4ft. (5 m) from a local hub to the attached local equipment;

16.4ft. (5 m) from each remote unit to the attached remote equipment;

164 ft. (50 m) between a local hub and any Micro remote unit; 1000 ft. (304.8 m) between a local hub and any other

type of remote unit;

ACUREM, ACUSREM, ACUVREM, ACUWREM, ACUREMSW, ACU1006MRA:

16.4ft. (5 m) from the remote to the attached remote equipment; 1000 ft. (304.8 m) between a local hub and any other

type of remote unit;

ACUMREM, ACU1006MRVA: 

16.4ft. (5 m) between the remote and the attached remote equipment;

150 ft. (45.7 m) between a local hub and the micro remote unit

NOTE: With high-quality cables, it might be possible to run farther than 16.4 ft. (5 m) from the hub or a remote unit to attached equipment.

Resolution (Maximum) —

ACUREM, ACUSREM, ACUVREM, ACUREMSW: 1600 x 1280: 200 ft. (61 m);

1280 x 1024: 300 ft. (91.4 m);

1024 x 768: 1000 ft. (304.8 m);

ACUMREM, ACUWREM:

1280 x 1024: 150 ft. (45.7 m) Serial Characteristics —

ACU1006SRA, ACU1006DSRA, ACUSREM:  Data rate: 9600 bps or 9.2 kbps, user selectable; Data format: 8 data bits, no parity, 1 stop bit (fixed);

ACU1006VRA, ACU1006DVRA, ACUWREM:  Data rate: Up to 19.2 kbps;

Data format: 8 data bits, no parity, 1 stop bit (fixed); ACUVREM, ACU1006MRVA: 

Data rate: Up to 19.2 kbps;

Data format: 8 data bits, no parity, 1 stop bit;

ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA, ACU1006DSRA, ACUREM, ACUSREM, ACUMREM, ACUREMSW, ACU1006MRA:

Flow control:

Hardware: RTS/CTS passed through or looped back, DTR/DSR passed through or looped back, or none (user-selectable);

Software: Transparent to software flow control;

ACU1006VRA, ACU1006DVRA, ACUVREM, ACUWREM, ACU1006MRVA: Flow control: Transparent to hardware and software flow control

(RTS, CTS, DTR, and DSR are all passed through across the link) Synchronization — H/V or composite, TTL signal levels;

sync polarity is preserved Video Bandwidth (to -3 dB) —

ACU1006RA, ACU1012RA, ACU1006DRA, ACU1006SRA, ACU1006DSRA, ACU1006VRA, ACU1006DVRA: 150 MHz per port;

ACUREM, ACUSREM, ACUVREM, ACUREMSW, ACU1006MRVA: Intrinsic: 300 MHz;

Across 328 ft. (100 m) UTP: 95 MHz (with equalization) Video Compensation —

With ACUMREM, ACUWREM, ACU1006MRA: For short- or long-distance (user-selectable);

With all other remote units: 3-stage continuously variable Video Coupling — DC

Video I/O Signal Levels — 0.7 volts peak to peak

User Controls —

ACU1006SRA, ACU1006DSRA:

(6) internal data-rate jumpers (1 for each port);

(6)internal flow-control jumper blocks (1 for each port);

ACUREM, ACUSREM, ACUVREM, ACUREMSW:

(2) front-mounted dials: Brightness and Focus;

(3)internal video-distance (cable-length) jumpers;

(1) internal 4-position DIP switch for various options;

ACUSREM:

(1)internal data-rate jumper;

(1)internal flow-control jumper block;

ACUMREM, ACUWREM:

(1)bottom-mounted 2-position DIP switch for video distance (cable length) and keyboard-command recognition;

ACU1006MRA, ACU1006MRVA:

(6)internal 2-position DIP switches for video distance and keyboard- command recognition, (1) for each local-to-remote link;

ACUVREM, ACUWREM only:

(1)internal microphone-amplification jumper; ACU1006MRVA only:

(6)internal microphone-amplification jumpers, (1) for each local-to-remote link

Mean Time Between Failure (MTBF) — 40,000 hours

Interface —

Between local hubs and remote units: Proprietary composite of all supported types of computer I/O;

On local hubs to CPUs:

Proprietary composite of VGA-compatible video and IBM  PS/2 compatible keyboard and mouse;

ACU1006SRA, ACU1006DSRA, ACU1006VRA only: TIA/EIA RS-232 (DCE);

ACU1006VRA, ACU1006DVRA only: Bidirectional 3.5-mm mini stereo audio;

ACU1006DRA, ACU1006DSRA, ACU1006DVRA: To local monitor: VGA;

To local keyboard and mouse: IBM PS/2 compatible; Remote units: Depending on the type of unit, either separate

or proprietary composite VGA video and IBM PS/2 compatible keyboard and mouse;

ACUREM, ACUSREM, ACUVREM, ACUREMSW, ACU1006MRVA only: TIA/EIA RS-232 (DTE);

ACUVREM, ACUWREM, ACU1006MRVA: 3.5-mm mini stereo audio

02/04/2010

#24985

724-746-5500

blackbox.com

­3 of 5

Page 3
Image 3
Black Box 24985 manual Type of remote unit, 1280 x 1024 300 ft .4 m 1024 x 768 1000 ft .8 m, Flow control