CATEGORY 5 PRIMARY AND SECONDARY SURGE PROTECTORS
Table
Typical Attenuation Measurements
Attenuation Measurements for the Primary Surge Protector (SP250A)
Freq. | Pins | Pins | Pins | Pins | SPEC |
(MHz) | (dB) | (dB) | (dB) | (dB) | (dB) |
1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 |
4 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 |
8 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 |
10 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 |
16 | 0.0 | 0.0 | 0.0 | 0.0 | 0.2 |
20 | 0.0 | 0.0 | 0.1 | 0.0 | 0.2 |
25 | 0.1 | 0.0 | 0.0 | 0.0 | 0.2 |
31.25 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 |
62.5 | 0.2 | 0.1 | 0.2 | 0.3 | 0.3 |
100 | 0.2 | 0.2 | 0.3 | 0.3 | 0.4 |
Attenuation Measurements for the Secondary Surge Protector (SP251A)
Freq. | Pins | Pins | Pins | Pins | SPEC |
(MHz) | (dB) | (dB) | (dB) | (dB) | (dB) |
1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 |
4 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 |
8 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 |
10 | 0.0 | 0.0 | 0.0 | 0.0 | 0.1 |
16 | 0.0 | 0.0 | 0.1 | 0.0 | 0.2 |
20 | 0.0 | 0.0 | 0.1 | 0.1 | 0.2 |
25 | 0.1 | 0.0 | 0.0 | 0.0 | 0.2 |
31.25 | 0.1 | 0.0 | 0.1 | 0.2 | 0.2 |
62.5 | 0.2 | 0.0 | 0.3 | 0.3 | 0.3 |
100 | 0.1 | 0.1 | 0.3 | 0.3 | 0.4 |