Blaupunkt manual Blaupunkt Specifications VA1400, 1 Channel Amplifier

Models: VA1400

1 14
Download 14 pages 3.38 Kb
Page 2
Image 2

BLAUPUNKT SPECIFICATIONS - VA1400, 1 CHANNEL AMPLIFIER

All power ratings conform to CEA-2006 standards.

PARAMETER/FEATURE

 

VA1400

Channels

 

1

 

 

 

Size ( L x W x D) without trim panels

 

15.1x9.1x2.4 inches (382x231x60mm)

 

 

 

Weight

 

14.5 lbs. (6.6 kg)

 

 

 

Spade screw speaker terminals?

 

YES

 

 

 

Maximum terminal wire size

 

10 ga.

 

 

 

Subsonic filter

 

YES (10 Hz)

 

 

 

Separate front/rear or left/right gains?

 

N/A

 

 

 

Fuse Type

 

ATC spade -Two 40A

 

 

Speaker short, short to +12V, and short to ground protection?

YES

 

 

 

High, low, and reverse voltage protection?

 

YES

 

 

 

Power output transistors

 

Low QZ MOSFET

 

 

 

Power supply transistors

 

MOSFET

 

 

 

Minimum speaker impedance

(non-bridged)

2 ohms

 

 

 

 

(bridged)

N/A

 

 

 

PERFORMANCE DATA

 

 

Rated power output @ 0.1% THD, 14.4V (CEA-2006)

 

 

 

 

1 channel into 4 ohms

(watts rms)

1 x 100 W

 

 

 

1 channel into 2 ohms

(watts rms)

1 x 600 W

 

 

 

Max Dynamic Power (watts rms)

 

700W

 

 

 

Total Harmonic Distortion @ full power

 

0.3% THD

 

 

 

Signal/Noise ratio (gain controls in center)

 

 

 

 

 

Measured @ 1 watt / 1 kHz

dBA

>80

 

 

 

Measured @ full rated power (0.1% THD)

dBA

>100

 

 

 

Damping factor

 

>100

 

 

 

Frequency response (full-range mode)

 

50 - 250 Hz

 

 

 

High-pass crossover frequency limits

 

N/A

 

 

 

Low-pass crossover frequency limits

 

50 H z - 250 Hz (variable), 12dB/oct

 

 

 

Input impedance

 

10 kohms

 

 

 

Input signal voltage control range

 

0.3 - 8.0 vrms

 

 

Current Draw @ 13.8 VDC (typical values @ X watts / Efficiency %)

 

 

 

 

@ full rated power, unbridged

(@ 4 ohms)

50 A (50%)

 

 

 

@ 33% rated power, unbridged

(@ 4 ohms)

30 A (35%)

 

 

 

@ idle

(@ 4 ohms)

1 A

 

 

Minimum battery voltage to maintain rated power

12.6 VDC

 

 

 

Usable battery voltage

 

10 - 16 VDC

 

 

 

Trigger line voltage range

 

10 - 16 VDC

 

 

 

Trigger line current draw

 

< 20 mA

 

 

 

Turn on delay time

 

@ 2.0 seconds

 

 

Thermal shutoff temperature (average heat-sink temp)

@ 85˚ C (185˚ F)

 

 

 

This information is subject to change without notice!