Blodgett B48--TTTT MODELS B48-GGGGAND B48-TTTT, Utility Information, Other Technical Information

Models: B48-GGGG B48--TTTT

1 2
Download 2 pages 29.37 Kb
Page 2
Image 2
MODELS B48-GGGG AND B48-TTTT

MODELS B48-GGGG AND B48-TTTT

APPROVAL/STAMP

36”

(914)

TOP VIEW

48” (1219)

36” Flue Riser

24” Flue Riser

5” Flue Riser

 

 

 

Minimum clearance from noncombustible

 

 

 

 

 

 

 

 

 

 

construction is zero.

 

 

SHIPPING CRATE DIMENSIONS & WEIGHT

 

 

 

Minimum clearance from combustible

 

 

 

 

(Door entry clearance when uncrated is 38” for all models,

 

38-3/4”

 

construction is 10” on sides and 12” on rear.

24”

 

 

except convection ovens, which is 41”.

 

(610)

(984)

 

 

 

 

The flue riser is installed on-site)

 

 

 

 

 

 

 

Model

Width

Height

Depth

Volume

Weight

 

 

 

 

B48A-GGGG/TTTT

45.5

45.0

55.0

65.2 cu ft

729 lbs

7” (178)

 

8-1/2” (216)

(1156)

(1143)

(1397)

(1.85 cu m)

(330 kg)

 

B48D-GGGG/TTTT

45.5

45.0

55.0

65.2 cu ft

676 lbs

 

 

 

 

 

 

 

 

(1156)

(1143)

(1397)

(1.85 cu m)

(306 kg)

 

 

 

 

B48N-GGGG/TTTT

45.5

23.0

55.0

33.3 cu ft

395 lbs

 

2” (51)

 

 

(1156)

(584)

(1397)

(0.95 cu m)

(179 kg)

 

 

SIDE VIEW of MODULAR MODEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41-3/4” (1060)

 

Dimensions are in inches and (millimeters)

 

 

 

 

Flue riser for “deep” depth-option extends rearward 6”

 

 

 

 

38” (965)

 

 

 

 

(cooking surface area is same as for “standard”depth).

 

 

 

 

35-3/4” (908)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32” (813)

 

 

 

 

 

 

 

 

 

 

Front Gas

2-1/2” (64)

 

 

 

 

 

 

Electrical

 

 

72”

Manifold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection

 

 

 

 

 

 

 

 

 

 

 

(1829)

 

 

Rear Gas

 

 

 

 

 

 

 

 

 

 

 

for Oven

 

60”

 

 

 

 

Manifold

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

 

(1524)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41”

 

 

33-3/4”

 

 

 

 

 

 

 

 

(1041)

 

 

 

 

 

 

 

 

 

 

 

 

(859)

 

 

 

 

 

 

 

 

 

 

 

Motor for

 

 

7" (178)

 

 

 

 

 

 

 

 

20”

 

2-1/2" (64)

18”

 

 

 

 

Convection

 

 

 

 

 

 

15-3/4”

(508)

 

 

 

(457)

 

 

 

Oven Model

 

 

 

 

 

 

 

(400)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT VIEW

SIDE VIEW

REAR VIEW

SHORT FORM SPECIFICATIONS

The item shall be a 48"-wide front-manifold sectional range with full width (thermostatic) griddle with four 32,000 BTU sections, a 1” thick steel surface with side splashers, and a grease drawer with a capacity of 3/4 gallon. The item shall have a 7" front rail and a belly bar. The item shall have 6" adjustable legs [casters]. The item shall have a [5" 24" 36"] flue riser able to support 250 pounds. The exterior (except for the back) shall be constructed of 430 stainless steel #3 polish. If the item is at the end of a battery, the end side shall be solid (rather than have a coverplate over the end of the front manifold).

Model 48A: The item shall have a 12” wide cabinet and 36” wide, 45,000 BTU convection oven with standing pilot and a thermostat range of 150°F to 550°F (66°C to 288°C). The oven interior shall be porcelain, measure 14" high x 26" wide x 24" deep, and have two racks with five-position side-rails with 2-1/4" between positions. The blower fan shall have two speeds and a 1/3 hp motor.

Model 48D: The item shall have a 12” wide cabinet and 36” wide 45,000 BTU standard oven with standing pilot and a thermostat range of 150°F to 550°F (66°C to 288°C). The oven interior shall be porcelain, measure 14" high x 26" wide x 26.5" deep, and have two racks with five-position side-rails with 2-1/4" between positions.

UTILITY INFORMATION

 

GAS: Each unit has a 1-1/4" front gas manifold that couples to the adjacent sectional unit(s), and can be

 

 

 

 

 

ordered with a 1" rear gas connection with a male NPT connector. Minimum supply pressure is 7" W.C.

MODEL

GAS (BTU/hr)

ELECTRICITY (amp)

for natural gas, 11" W.C. for propane. An external pressure regulator and shut off valve must be provid-

Natural Gas

Propane

120V

208/240V

ed. If using a flexible-hose gas connection, the I.D. of the hose must not be smaller than the connector

 

on the unit and must comply with ANSI Z21.69. Provide an adequate means of restraint to prevent

 

 

 

 

 

B48A-GGGG/TTTT

173,000

154,000

4.8

2.6

undue strain on the gas connection.

ELECTRICITY: Both standard-oven and convection-oven models require electric power (50Hz or 60Hz

 

 

 

 

 

B48D-GGGG/TTTT

173,000

154,000

1.0

1.0

single-phase AC). 120V models have a 7-foot (2134 mm) power cord with a grounded plug. 208/240V

 

 

 

 

 

models have a terminal block for connection to a single-phase 208/240V source.

B48N-GGGG/TTTT

128,000

112,000

-

-

FLUE EXHAUST: Installation under a vented hood is recommended.

 

 

 

 

 

 

OTHER TECHNICAL INFORMATION

Exterior surfaces are 430 stainless steel #3 polish, except the back is aluminized steel.

Each 12” section has a separate control knob located on the front panel. On oven models, a gas valve for the oven is located on the front panel above the oven. The oven control panel is located to the left of the oven door and includes an on-off switch, indicator light, thermostat knob, and (on convection ovens) a speed selector switch for the blower motor. The fan motor for convection ovens is 1/3 hp, 2-speed, 1725/1140 rpm, with overload protection. Check local codes for fire and sanitary regulations.

NOTE: The company reserves the right to make substitutions of components without prior notice

BLODGETT

www.blodgett.com

1100 Old Honeycutt Road Fuquay-Varina, NC 27526 USA • Phone: (877) 255-3976 • Fax: (866) 644-1354

Printed in U.S.A.

NOTE: FOR COMMERCIAL USE ONLY

P/N BR00015 Rev D (6/08)

Page 2
Image 2
Blodgett B48--TTTT MODELS B48-GGGGAND B48-TTTT, Utility Information, Other Technical Information, Approval/Stamp, Blodgett