7.1.2 WATER SUPPLY CONNECTION
Water supply may be connected to the dishwasher in one of two ways:
• With metal braided hose.
• With copper tubing.
7.1.3 BRAIDED HOSE/COPPER TUBING
After connections are made turn on the water supply to check for leaks.
CAUTION
•Hot water supply line: Use minimum 3/8” O.D. copper tubing or metal braided dishwasher supply line.
•Temperatures required for soldering and sweating will damage the dishwasher’s water inlet valve so if any such operation is needed, keep the heat source min. 77/8” (200mm) away from the dishwasher’s water inlet valve.
•There should not be any sharp bends in the water line that may restrict the water flow.
•Teflon tape or pipe tread compound must be used for sealing the connection. Before connecting the copper water supply line to the dishwasher, flush it with hot water to clear any foreign material.
Notice :
After connections are made turn on the water supply to check for leaks.
7.2ELECTRICAL CONNECTION WARNING
•Make sure the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent injury and machine damage. Consult a qualified electrician if in doubt.
•Only connect the dishwasher to the mains when all installation and plumbing work is complete.
•Do not use any extension cord or portable outlet device to connect the dishwasher to a power supply.
•The
•The access hole of the supply cord to the installation compartment must be smooth and rounded and it must be large enough for the attachment plug to pass through. The longest dimension of the opening shall not be more than 1,5” (38 mm).If the partition is metal, it needs to be covered with the edge protector (m).
•Care must be taken when the appliance is installed or removed, to reduce the likelihood of damage to the
7.2.1GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an
WARNING
•Improper connection of the