Outdoor LP Gas Barbecue Grill Model No. GBC750W
To operate you will need (1)
Note: An empty standard grill LP gas tank weighs approximately 18 lbs. A
Place precision filled LP gas tank upright into hole in grill body so it is arranged for vapor withdrawal.
Checking for Leaks | LP Gas |
| |
| Connection |
Burner Connections
Make sure the regulator valve and hose connections are securely fastened to the burner and the tank.
If your unit was assembled for you, visually check the connection between the burner pipe and orifice. Make sure the burner pipe fits over the orifice.
|
| WARNING |
|
|
|
| |
|
| FOR YOUR SAFETY: |
|
| Failure to inspect this connection or | LP Gas | |
| follow these instructions could cause | Connection | |
|
| ||
| a fire or an explosion which can |
| |
| cause death, serious bodily injury, or |
| |
| damage to property. |
| |
|
|
|
|
Please refer to diagram for proper installation.
If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance.
Tank/Gas Line Connection
Make
Make sure control knobs are off.
Burner venturi
LP Gas Valve Main Burners with Orifice
LP Gas Valve with Orifice
| Burner |
Side Burner | venturi |
Secure tank by sliding tank retainer wire over shoulder of LP gas tank.
Turn LP gas tank ON at valve.
Spoon leak check solution at all “x” locations
If any bubbles appear turn LP gas tank OFF, reconnect and
If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed.
X
X
X
X X
LP Gas Tank Valve
Before connecting, be sure that there is no debris caught in the head of the LP gas tank, head of the regulator valve or in the head of the burner and burner ports.
Connect gas line to tank by turning knob clockwise until it stops.
Disconnect LP Gas TankBefore disconnecting make sure the LP gas tank valve OFF.
Lighting
1.Open lid. Attempting to light the burner with the lid closed may cause an explosion!
2.Make sure there are no obstructions of airflow to the gas unit. Spiders and insects can nest within and clog the burner / venturi tube at the orifice. A clogged burner tube can lead to a fire beneath the appliance.
3.All control knobs must be in the OFF position.
4.Turn on gas at LP gas tank.
5.Push and turn control knob c ounterclockwise to HIGH.
6.Press the electronic igniter button and hold for 5 seconds to light burner.
7.If ignition does not occur in 5 seconds, turn burner control knob OFF, wait 5 minutes, and repeat lighting procedure.
8.If igniter does not light burner, use a lit match secured with the lighting rod provided to light burners manually. Access the burners through the cooking grid and heat plates. Position the lit match near side of the burner.
Control Knob
Main Burner Lighting Rod Placement
Flame Slight
Yellow
Slight
Disconnect gas line to tank by turning knob
Important: Always use the lighting rod provided when lighting burners with a match.
Burner
Blue
counterclockwise until it is loose.
9.After lighting, observe the burner flame, make sure all burner ports are lit and flame height matches illustration.
Dark
Blue
Main burner proper flame height.
Need a tank of gas? Try tank exchange service. It’s easy, fast, safe, and available at tens of thousands of conveniently located retail outlets nationwide. You can purchase a new full tank or exchange your empty for a precision filled one.
If burner flame goes out during operation, immediately turn the gas “OFF” and open lid to let the gas clear for about 5 minutes before