page no.

Contact 1.800.762.1142 for assistance. Do not return to place of purchase.

Installing LP Gas Tank
Operating Instructions

To operate you will need (1) precision-filled standard grill LP gas tank (20#) with external valve threads.

Note: An empty standard grill LP gas tank weighs approximately 18 lbs. A precision-filled standard grill LP gas tank should weigh no more than 38 lbs.

Insert LP Gas Tank

Place precision filled LP gas tank upright into hole in grill body so the tank valve is facing the gas line connection.

Checking for LeaksBurner Connections

1.Make sure the regulator valve and hose connections are securely fastened to the burner and the tank.

If your unit was assembled for you, visually check the connection between the burner venturi pipe and orifice. Make sure the burner venturi pipe fits over the orifice.

WARNING: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property.

2.Please refer to diagram for proper installation. (Figure 1 and 2)

3.If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance.

LP Gas Connection

Figure 1

Burner venturi

LP Gas Valve Main Burners with Orifice

Figure 2

Secure LP Gas TankSecure tank by sliding tank retainer wire over shoulder of LP gas tank.
Tank/Gas Line Connection

1.Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.

2.Make sure control knobs are “OFF”. (Figure 2)3.Turn LP gas tank “ON” at valve.4.Spoon leak check solution at all “X” locations (Figure 4)a.If any bubbles appear turn LP gas tank “OFF”, reconnect and re-test.

b.If you continue to see bubbles after several attempts, turn LP gas tank “OFF” and disconnect LP gas tank and contact 1.800.762.1142 for assistance.

c.If no bubbles appear after one minute turn tank “OFF”, wipe away solution and proceed.

Figure 4

X

X

X

X X

Connect LP Gas Tank

Before connecting, be sure that there is no debris caught in the head of the LP gas tank, head of the regulator valve or in the head of the burner and burner ports.

Connect gas line to tank by turning knob clockwise until it stops.Disconnect LP Gas TankBefore disconnecting make sure the LP gas tank valve is “OFF”.

Disconnect gas line from LP gas tank by turning knob counterclockwise until it is loose.

Need a tank of gas? Try tank exchange service. It’s easy, fast, safe, and available at tens of thousands of conveniently located retail outlets nationwide. You can purchase a new full tank or exchange your empty for a precision filled one.

Operating Main Burners
First Use

Figure 5

 

1.Make sure all labels, packaging and protective films have been removed from the grill.

2.Remove manufacturing oils before cooking on this grill for the first time, by operating the grill for at least 15 minutes on “HIGH” with the lid closed. This will “heat clean” the internal parts and dissipate odors.

Lighting

 

 

 

 

1. Open lid. Attempting to light the burner with the

 

 

 

 

lid closed may cause an explosion!

 

 

 

 

2. Make sure there are no obstructions of airflow to

 

 

 

 

the burners. Spiders and insects can nest within

 

 

 

 

and clog the burner / venturi tube at the orifice. A

 

 

 

 

clogged burner tube can lead to a fire beneath the

 

 

 

 

appliance.

 

 

 

 

3. All control knobs must be in the “OFF” position.

 

 

 

 

(Figure 2)

 

 

 

 

4. Turn ON gas at LP gas tank.

 

 

 

 

5. Push and turn control knob counterclockwise to

 

 

 

 

“HIGH”.

 

 

 

 

6. Press the electronic igniter button and hold for 5

 

 

 

 

seconds to light burner.

 

 

 

 

7. If ignition does not occur in 5 seconds, turn burner

 

Figure 6

 

 

control knob “OFF”, wait 5 minutes, and repeat

 

 

 

 

 

Flame

Slight

 

lighting procedure.

 

 

 

Yellow

 

8. If igniter does not light burner, use a lit match

 

 

 

 

 

Slight

 

secured with the lighting rod provided to light

 

 

 

 

 

Blue

 

burners manually. Access the burners through the

Burner

 

 

 

 

 

cooking grid and heat plates. Position the lit match

 

 

Dark

 

near side of the burner. (Figure 4)

 

 

Blue

 

Important: Always use the lighting rod provided when

 

 

 

 

 

 

 

 

lighting burners with a match.

 

 

 

 

9. After lighting, observe the burner flame, make sure

 

 

 

 

all burner ports are lit and flame height matches

 

 

 

 

illustration. (Figure 5)

 

 

 

 

Caution: If burner flame goes out during operation, immediately turn the gas “OFF” and open lid to let the gas clear for about 5 minutes before re- lighting.