Outdoor Patio Heater Model No. GWU9300H
Troubleshooting
If the problem is: | And this condition exists: | Then do this | |
Pilot won’t light | Tank valve is closed | Open valve | |
|
|
| |
| Blockage in orifice or pilot tube | Clean or replace orifice or pilot tube | |
|
|
| |
| Air in gas line | Open gas line and bleed it (pressing control knob in) for not more | |
Note: Heater operates at reduced efficiency below 40ºF (5ºC). |
| than 1 - 2 minutes or until you smell gas | |
|
|
| |
| Low gas pressure with tank valve fully open | Turn tank valve “OFF” and replace tank | |
|
|
| |
| Igniter fails | Use match to light pilot; obtain new igniter and replace | |
|
|
| |
Pilot won’t stay lit | Dirt built up around pilot | Clean dirt from around pilot | |
|
|
| |
| Connection between gas valve and pilot assembly is loose | Tighten connection and perform leak check | |
|
|
| |
| Thermocouple is not operating correctly | Replace thermocouple | |
|
|
| |
Burner won’t light | Gas pressure is low | Turn tank valve “OFF” and replace tank | |
|
|
| |
| Blockage in orifice | Clear blockage | |
|
|
| |
| Control knob is not in “ON” position | Turn control knob to “ON” | |
|
|
| |
Burner flame is low | Gas pressure is low | Turn tank valve “OFF” and replace tan | |
|
|
| |
| Outdoor temperature is less than 40ºF and tank is less than 1/4 | Use a full tank | |
| full |
| |
|
|
| |
| Supply hose is bent or kinked | Straighten hose | |
|
|
| |
| Control knob fully “ON” | Check burner and orifices for blockage | |
|
|
| |
Emitter glows uneven | Gas pressure is low | Turn tank valvue “OFF” and replace tank | |
|
|
| |
| Base is not on a level surface | Place heater on a level surface | |
Note: Bottom 1” of emitter normally does NOT glow. |
|
| |
Heater is level | Clean burner | ||
| |||
|
|
| |
Carbon | Dirt or film on reflector and emitter | Clean reflector and emitter | |
|
|
| |
Thick black smoke | Blockage in burner | Remove blockage and clean burner inside and outside | |
|
|
|
For more assistance please visit us online at www.bluerhino.com or call 1.800.762.1142 for immediate assistance.
Specifications
Certifications:CSA International Requirement 5.90
Canadian National Standard
Maximum 40,000 BTU/hr. input
Heat Range:Up to 20 foot diameter
Fuel:Liquid Propane Gas (LP)
Tank Size:Nominal 20 lb / 5 Gallon
Inlet gas supply pressure:Maximum – 150 PSI
Minimum – 5 PSI
Manifold Pressure:11.00 in. W.C.
Engine:IPP E1
Safety Features:100% Burner
Blue Rhino Global Sourcing, Inc
Made In:China